Coleman / AIR-SOURCE HEAT PUMP

THF2B60T21

LX SERIES · source records, page 8

191 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16191 / 191
EER2 · BTU/Wh11–12191 / 191
HSPF2 · BTU/Wh7.8–8.1191 / 191
Cooling capacity · BTU/h53,000–57,000191 / 191
Heating capacity at 47°F / 8.3°C · BTU/h54,500–59,500191 / 191
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000191 / 191
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800191 / 191
COP at 5°F / −15°C2–2.46191 / 191
Equipment / loop typeHP - Split System191 / 191
Refrigerant / source-reported GWPR-410A (GWP:2088)191 / 191
Compressor stagingTwo-stage191 / 191
Connected capabilityNo191 / 191

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC60HXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21035348315.208.10310002.24EPA 4049041 →
XAFC60HXXN1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21241461315.208.10318002.32EPA 4049062 →
XAFD60HXXN1+TXV+ furnace: TM9V120D20MP12AHRI reference: 21035345315.208.10308002.22EPA 4049069 →
XAFD60HXXN1+TXV+ furnace: TP9C120D20MP13AHRI reference: 21035345715.208.10308002.22EPA 4049073 →
XAHD60JBCN1+ furnace: CP9C120D20MP13AHRI reference: 21035340715.208.10300002.02EPA 4049090 →
XAFD60HBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21035350915.208.10314002.22EPA 4049116 →
XAHD60JXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21035526515.208.10300002.00EPA 4049121 →
XAHD60JBCN1+ furnace: TM9E100C20MP12AHRI reference: 21035527115.208.10300002.00EPA 4049127 →
XAFD60JXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21035527715.208.10314002.22EPA 4049133 →
XAFD60JBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21035530315.208.10314002.22EPA 4049157 →
XAFD60JBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21035530915.208.10314002.22EPA 4049164 →
XAFD60HBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21035352115.208.10314002.22EPA 4049168 →
XAFC60HBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241461815.208.10318002.32EPA 4049188 →
XAFD60HBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 21247621415.208.10314002.34EPA 4049192 →
XAFD60JXXN1+TXV+ furnace: Z8ES120C20LMPS1AHRI reference: 21247662215.208.10314002.38EPA 4049200 →
XAFD60JXXN1+TXV+ furnace: Z8ES120C20SMPS1AHRI reference: 21241516715.208.10314002.38EPA 4049208 →
XAFD60JBCN1+ furnace: Z9ET120D20SMPS1AHRI reference: 21241480815.208.10316002.32EPA 4049213 →
XAFC60HXXN1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21247850015.208.10318002.32EPA 4049236 →
XAFC60HBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247851215.208.10318002.32EPA 4049243 →
XAFD60JBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 21247662915.208.10314002.38EPA 4049260 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.