THF2B60T21
LX SERIES
191 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 191 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 191 / 191 |
| EER2 · BTU/Wh | 11–12 | 191 / 191 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 191 / 191 |
| Cooling capacity · BTU/h | 53,000–57,000 | 191 / 191 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 54,500–59,500 | 191 / 191 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,400–39,000 | 191 / 191 |
| Heating capacity at 5°F / −15°C · BTU/h | 29,200–32,800 | 191 / 191 |
| COP at 5°F / −15°C | 2–2.46 | 191 / 191 |
| Equipment / loop type | HP - Split System | 191 / 191 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 191 / 191 |
| Compressor staging | Two-stage | 191 / 191 |
| Connected capability | No | 191 / 191 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHD60JBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 212414982 | 16.00 | 8.10 | 31200 | 2.36 | EPA 2484037 → |
XAFD60HXXN1+JMVT20DC2N1+TXVAHRI reference: 210351865 | 16.00 | 8.10 | 30800 | 2.22 | EPA 2786618 → |
XAFD60HXXN1+JMET18DS2N1+TXVAHRI reference: 210358460 | 16.00 | 8.10 | 30800 | 2.26 | EPA 2788228 → |
XAFD60JXXN1+JMVT20DC2N1+TXVAHRI reference: 210353429 | 16.00 | 8.10 | 30800 | 2.26 | EPA 2788766 → |
XAFD60JXXN1+JMET18DS2N1+TXVAHRI reference: 210361844 | 16.00 | 8.10 | 30600 | 2.22 | EPA 2814287 → |
JHVTD60JBCC2N1AHRI reference: 210353437 | 16.00 | 8.10 | 30600 | 2.22 | EPA 3557929 → |
JHVTD60HBCC2N1AHRI reference: 210361168 | 16.00 | 8.10 | 30600 | 2.28 | EPA 3558023 → |
JHETD60HBCS2N1AHRI reference: 210361172 | 16.00 | 8.10 | 30600 | 2.26 | EPA 3558027 → |
JHETD60JBCS2N1AHRI reference: 210361856 | 16.00 | 8.10 | 30800 | 2.24 | EPA 3558031 → |
XAFD60HBCN1+JMVT20DC2N1AHRI reference: 210351869 | 16.00 | 8.10 | 30800 | 2.22 | EPA 3985596 → |
XAFD60HBCN1+JMET18DS2N1AHRI reference: 210358466 | 16.00 | 8.10 | 30800 | 2.26 | EPA 3986726 → |
XAFD60JBCN1+JMVT20DC2N1AHRI reference: 210353433 | 16.00 | 8.10 | 30800 | 2.26 | EPA 3987857 → |
XAFD60JBCN1+JMET18DS2N1AHRI reference: 210361850 | 16.00 | 8.10 | 30600 | 2.22 | EPA 3988448 → |
XAFD60HBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 212414773 | 15.20 | 7.80 | 31000 | 2.34 | EPA 2476316 → |
XAFD60JBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 212415262 | 15.20 | 8.10 | 31400 | 2.42 | EPA 2476484 → |
XAHD60JBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 212415022 | 15.20 | 8.10 | 31000 | 2.38 | EPA 2476784 → |
XAHD60JBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 212481763 | 15.20 | 8.10 | 31200 | 2.36 | EPA 2476886 → |
XAFD60JXXN1+TXV+ furnace: Z8ES080C16LMPS1AHRI reference: 212481770 | 15.20 | 8.10 | 31400 | 2.42 | EPA 2476888 → |
XAHD60JXXN1+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 212481756 | 15.20 | 8.10 | 31200 | 2.36 | EPA 2477090 → |
XAHD60JXXN1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 212481742 | 15.20 | 8.10 | 31000 | 2.38 | EPA 2477163 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →