Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16390 / 390
EER2 · BTU/Wh11–12390 / 390
HSPF2 · BTU/Wh7.8–8.1390 / 390
Cooling capacity · BTU/h44,500–47,500390 / 390
Heating capacity at 47°F / 8.3°C · BTU/h43,500–47,500390 / 390
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,200390 / 390
Heating capacity at 5°F / −15°C · BTU/h23,400–29,800390 / 390
COP at 5°F / −15°C2.22–2.84390 / 390
Equipment / loop typeHP - Split System390 / 390
Refrigerant / source-reported GWPR-410A (GWP:2088)390 / 390
Compressor stagingTwo-stage390 / 390
Connected capabilityNo390 / 390

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC60HBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241399915.207.80252002.34EPA 2481607
XAHC60GBCN1+ furnace: Z8ET080B12LMPS1AHRI reference: 21241713515.207.80248002.34EPA 2481927
XAFD60HBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247842015.207.80250002.34EPA 2482092
XAHD60GBCN1+ furnace: Z8ES100C16SMPS1AHRI reference: 21241733515.207.80254002.34EPA 2483177
XAFC60HBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21248354015.207.80252002.34EPA 2485005
XAHC60GBCN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21241751015.207.80248002.34EPA 2485268
XAFD60HBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 21241806715.207.80252002.34EPA 2485276
XAFD60HBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21247846915.207.80252002.34EPA 2485353
XAFC60HBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21248650815.207.80252002.34EPA 2485370
XAFC60HBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 21241395415.207.80252002.32EPA 2485514
XAHD60HBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241376415.208.10240002.40EPA 2485587
XAFD60HBCN1+ furnace: TMLE100C16MP11AHRI reference: 21036011715.207.80238002.30EPA 3025776
XAHD60GBCN1+ furnace: TMLE130D20MP11AHRI reference: 21034443415.207.80244002.24EPA 3025853
XAHC60GBCN1+ furnace: TM8E120C20MP11AHRI reference: 21035958615.207.80240002.26EPA 3025862
XAHC60GBCN1+ furnace: TM8E080C20MP11AHRI reference: 21034449815.207.80242002.26EPA 3025866
XAHC60GBCN1+ furnace: TMLE120C16MP11AHRI reference: 21035961215.207.80244002.22EPA 3025868
XAHC60GBCN1+ furnace: TM8E120C16MP11AHRI reference: 21035960615.207.80244002.22EPA 3025872
XAHC60GBCN1+ furnace: TMLE080C20MP11AHRI reference: 21034450415.207.80242002.26EPA 3025877
XAHC60GBCN1+ furnace: TMLE120C20MP11AHRI reference: 21035959215.207.80240002.26EPA 3025884
XAHD60GBCN1+ furnace: TM8E080C20MP11AHRI reference: 21035962615.207.80242002.24EPA 3025885