Coleman / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 9

460 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 460 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16460 / 460
EER2 · BTU/Wh11.7–12460 / 460
HSPF2 · BTU/Wh7.8–8.1460 / 460
Cooling capacity · BTU/h39,500–42,000460 / 460
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000460 / 460
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600460 / 460
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600460 / 460
COP at 5°F / −15°C1.98–2.42460 / 460
Equipment / loop typeHP - Split System460 / 460
Refrigerant / source-reported GWPR-410A (GWP:2088)460 / 460
Compressor stagingTwo-stage460 / 460
Connected capabilityNo460 / 460

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFD60GXXN1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 21247716716.008.10208002.28EPA 3990489 →
XAFD60GXXN1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 21247716216.008.10208002.28EPA 3990492 →
XAFD60GBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 21247717416.008.10208002.28EPA 3990498 →
XAFD60GBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 21247718416.008.10208002.28EPA 3990504 →
XAFD60GBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21247791816.008.10208002.28EPA 3990542 →
XAFD60GXXN1+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 21248537616.008.10210002.26EPA 3990667 →
XAFD60GXXN1+TXV+ furnace: Z8ES080C20LMPS1AHRI reference: 21248538116.008.10210002.26EPA 3990669 →
XAFD60GBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 21248538816.008.10210002.26EPA 3990678 →
XAFD60GBCN1+ furnace: Z8ES080C20LMPS1AHRI reference: 21248539816.008.10210002.26EPA 3990683 →
XAHC60GBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21247731116.008.10218002.38EPA 3990713 →
XAHC60GBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21247730616.008.10218002.38EPA 3990715 →
XAFD60GXXN1+TXV+ furnace: Z8ET100C20LMPS1AHRI reference: 21259390616.008.10210002.26EPA 3990817 →
XAHD60GBCN1+ furnace: Z8ET120C20LMPS1AHRI reference: 21259390116.008.10218002.34EPA 3990819 →
XAFD60GBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 21259391116.008.10210002.26EPA 3990828 →
XAHD60GBCN1+ furnace: Z8ET080C16LMPS1AHRI reference: 21259392616.008.10220002.36EPA 3990832 →
XAFC60GBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 21248831016.008.10218002.26EPA 3990908 →
XAFC60GBCN1+ furnace: Z8ES080C20LMPS1AHRI reference: 21248832016.008.10218002.26EPA 3990916 →
XAHC60GBCN1+ furnace: Z8ET120C20LMPS1AHRI reference: 21259404116.008.10218002.36EPA 3991008 →
XAFC60GBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 21259405116.008.10208002.28EPA 3991013 →
XAHC60GBCN1+ furnace: Z8ET080C16LMPS1AHRI reference: 21259406616.008.10220002.38EPA 3991019 →