Coleman / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 18

460 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 460 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16460 / 460
EER2 · BTU/Wh11.7–12460 / 460
HSPF2 · BTU/Wh7.8–8.1460 / 460
Cooling capacity · BTU/h39,500–42,000460 / 460
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000460 / 460
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600460 / 460
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600460 / 460
COP at 5°F / −15°C1.98–2.42460 / 460
Equipment / loop typeHP - Split System460 / 460
Refrigerant / source-reported GWPR-410A (GWP:2088)460 / 460
Compressor stagingTwo-stage460 / 460
Connected capabilityNo460 / 460

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC48FXXN1+TXV+ furnace: TM9E100C20MP12AHRI reference: 21035176015.208.10196002.04EPA 3985573 →
XAFC48FBCN1+ furnace: TM9E100C20MP12AHRI reference: 21035176615.208.10196002.04EPA 3985575 →
XAFC48FXXN1+TXV+ furnace: TM8Y100C20MP11AHRI reference: 21035180215.208.10196002.04EPA 3985584 →
XAFC48FBCN1+ furnace: TM8Y100C20MP11AHRI reference: 21035181015.208.10196002.04EPA 3985588 →
XAFC48FBCN1+ furnace: TM9V100C16MP12AHRI reference: 21034771915.208.10195002.06EPA 3985859 →
XAFC48FBCN1+ furnace: TP9C100C16MP13AHRI reference: 21034772715.208.10195002.06EPA 3985862 →
XAFC48FBCN1+ furnace: CP9C100C16MP13AHRI reference: 21034773515.208.10195002.06EPA 3985868 →
XAHC48FBCN1+ furnace: TP9C080B12MP13AHRI reference: 21034775315.208.10195002.06EPA 3985872 →
XAHC48FBCN1+ furnace: TM9V080B12MP12AHRI reference: 21034774915.208.10195002.06EPA 3985874 →
XAHC48FBCN1+ furnace: CP9C080B12MP13AHRI reference: 21034775715.208.10195002.06EPA 3985876 →
XAFD48FBCN1+ furnace: TM9E120D20MP12AHRI reference: 21034776515.208.10193002.04EPA 3985883 →
XAHD48FBCN1+ furnace: TM9E100C20MP12AHRI reference: 21034777715.208.10198002.12EPA 3985886 →
XAFD48FBCN1+ furnace: TM9E100C20MP12AHRI reference: 21034778915.208.10196002.04EPA 3985889 →
XAFC48FXXN1+TXV+ furnace: TL9E080C16UH11AHRI reference: 21034796915.207.80196002.00EPA 3985895 →
XAFC48FBCN1+ furnace: TL9E080C16UH11AHRI reference: 21034797315.207.80196002.00EPA 3985898 →
XAFC48FXXN1+TXV+ furnace: TM8Y080C16MP11AHRI reference: 21034483415.208.10192002.04EPA 3986020 →
XAFC48FBCN1+ furnace: TM8Y080C16MP11AHRI reference: 21034484015.208.10192002.04EPA 3986024 →
XAFC48FXXN1+TXV+ furnace: TM8V080C16MP12AHRI reference: 21034485615.208.10192002.02EPA 3986031 →
XAFC48FXXN1+TXV+ furnace: TM8V100C16MP12AHRI reference: 21034485215.208.10192002.02EPA 3986033 →
XAFC48FBCN1+ furnace: TM8V100C16MP12AHRI reference: 21034487615.208.10192002.02EPA 3986037 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →