Coleman / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 11

460 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 460 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16460 / 460
EER2 · BTU/Wh11.7–12460 / 460
HSPF2 · BTU/Wh7.8–8.1460 / 460
Cooling capacity · BTU/h39,500–42,000460 / 460
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000460 / 460
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600460 / 460
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600460 / 460
COP at 5°F / −15°C1.98–2.42460 / 460
Equipment / loop typeHP - Split System460 / 460
Refrigerant / source-reported GWPR-410A (GWP:2088)460 / 460
Compressor stagingTwo-stage460 / 460
Connected capabilityNo460 / 460

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC60GBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248828415.958.10210002.28EPA 3990905
XAFD48FBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21247826615.208.10210002.24EPA 2476278
XAHC48FBCN1+ furnace: Z9ET100C16SMPS1AHRI reference: 21241545215.207.80216002.32EPA 2476619
XAFC48FXXN1+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 21241640015.208.10208002.20EPA 2476991
XAFC48FBCN1+ furnace: Z8ES100B12LMPS1AHRI reference: 21248288515.207.80212002.20EPA 2477145
XAFC48FBCN1+ furnace: Z8ET100C16LMPS1AHRI reference: 21241599515.207.80206002.18EPA 2477171
XAFC48FXXN1+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 21248278915.208.10210002.22EPA 2477223
XAFC48FXXN1+TXV+ furnace: Z8ET100C16LMPS1AHRI reference: 21241599015.208.10208002.22EPA 2477226
XAFD48FBCN1+ furnace: Z9ET120D20SMPS1AHRI reference: 21241538715.207.80208002.18EPA 2477238
XAFC48FXXN1+TXV+ furnace: Z8ES100C16SMPS1AHRI reference: 21241626015.208.10210002.22EPA 2477283
XAHC48FBCN1+ furnace: Z8ET100C16LMPS1AHRI reference: 21241597515.207.80218002.36EPA 2478402
XAFD48FBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 21248574215.208.10212002.20EPA 2478764
XAFC48FXXN1+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21248286015.207.80212002.20EPA 2478805
XAFC48FBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 21248281415.208.10210002.22EPA 2479516
XAFD48FBCN1+ furnace: Z8ES100C16LMPS1AHRI reference: 21248577015.208.10210002.22EPA 2479971
XAFD48FBCN1+ furnace: Z9ES120D20SMPS1AHRI reference: 21241558315.208.10208002.24EPA 2481578
XAFD48FBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21241616515.208.10210002.24EPA 2481677
XAFC48FBCN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21241640515.208.10208002.20EPA 2481841
XAFC48FXXN1+TXV+ furnace: Z8ES100C16LMPS1AHRI reference: 21248862915.208.10210002.22EPA 2482912
XAFC48FXXN1+TXV+ furnace: Z8ES120C20LMPS1AHRI reference: 21248859615.207.80212002.20EPA 2482921

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →