Coleman / AIR-SOURCE HEAT PUMP

THF2B30T21

LX SERIES · source records, page 6

266 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity28,400–30,600BTU/h

Each efficiency range summarizes published EPA records for THF2B30T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 266 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16266 / 266
EER2 · BTU/Wh11.7–12266 / 266
HSPF2 · BTU/Wh7.8–8.1266 / 266
Cooling capacity · BTU/h28,400–30,600266 / 266
Heating capacity at 47°F / 8.3°C · BTU/h27,000–29,200266 / 266
Heating capacity at 17°F / −8.3°C · BTU/h17,500–19,100266 / 266
Heating capacity at 5°F / −15°C · BTU/h13,600–18,600266 / 266
COP at 5°F / −15°C2.02–2.76266 / 266
Equipment / loop typeHP - Split System266 / 266
Refrigerant / source-reported GWPR-410A (GWP:2088)266 / 266
Compressor stagingTwo-stage266 / 266
Connected capabilityNo266 / 266

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC48FBAN1+ furnace: Z8ET080B12LMPS1AHRI reference: 21259415716.007.80153002.28EPA 3991061 →
XAHC48FBAN1+ furnace: Z8ET080B12LMPS1AHRI reference: 21259430216.007.80144002.16EPA 3991224 →
XAHC36DBAN1+ furnace: Z8ET080B12LMPS1AHRI reference: 21259463716.007.80145002.18EPA 3991446 →
XAFC48FXXN1+TXV+ furnace: Z8ET080C16LMPS1AHRI reference: 21259464216.008.10152002.34EPA 3991447 →
XAFC48FBAN1+ furnace: Z8ET080C16LMPS1AHRI reference: 21259464716.008.10152002.34EPA 3991456 →
XAHB36DBAN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21248838715.207.80145002.18EPA 2480724 →
XAHB36DBAN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21248838215.207.80145002.18EPA 2481062 →
XAFB36DXXN1+TXV+ furnace: Z8ES080B12SMPS1AHRI reference: 21247734215.208.10157002.26EPA 2482126 →
XAFB36DBAN1+ furnace: Z8ES080B12LMPS1AHRI reference: 21247736415.208.10157002.26EPA 2482144 →
XAHC36DBAN1+ furnace: Z8ES100B12SMPS1AHRI reference: 21247519715.207.80147002.20EPA 2484097 →
XAHC36DBAN1+ furnace: Z8ES100B12LMPS1AHRI reference: 21247520715.207.80147002.20EPA 2484101 →
XAFB36DXXN1+TXV+ furnace: Z8ES080B12LMPS1AHRI reference: 21247734715.208.10157002.26EPA 2485914 →
XAFB36DBAN1+ furnace: Z8ES080B12SMPS1AHRI reference: 21247735415.208.10157002.26EPA 2485918 →
XAFD48FBAN1+ furnace: TM9E080C16MP12AHRI reference: 21034365415.207.80139002.08EPA 2785609 →
XAFD48FBAN1+ furnace: TM8Y100C16MP11AHRI reference: 21034367415.208.10142002.12EPA 2785616 →
XAFD48FBAN1+ furnace: TM8Y080C16MP11AHRI reference: 21034368215.207.80140002.10EPA 2785619 →
XAFC36DBAN1+ furnace: TP9C080B12MP13AHRI reference: 21035193515.207.80145002.12EPA 2786642 →
XAFC36DBAN1+ furnace: CP9C080B12MP13AHRI reference: 21035193915.207.80145002.12EPA 2786643 →
XAFC36DBAN1+ furnace: TM9V080B12MP12AHRI reference: 21035193115.207.80145002.12EPA 2786652 →
XAFC36DBAN1+ furnace: TM9E080B12MP12AHRI reference: 21035199715.207.80144002.10EPA 2786688 →