Coleman / AIR-SOURCE HEAT PUMP

THF2B30T21

LX SERIES · source records, page 13

266 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity28,400–30,600BTU/h

Each efficiency range summarizes published EPA records for THF2B30T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 266 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16266 / 266
EER2 · BTU/Wh11.7–12266 / 266
HSPF2 · BTU/Wh7.8–8.1266 / 266
Cooling capacity · BTU/h28,400–30,600266 / 266
Heating capacity at 47°F / 8.3°C · BTU/h27,000–29,200266 / 266
Heating capacity at 17°F / −8.3°C · BTU/h17,500–19,100266 / 266
Heating capacity at 5°F / −15°C · BTU/h13,600–18,600266 / 266
COP at 5°F / −15°C2.02–2.76266 / 266
Equipment / loop typeHP - Split System266 / 266
Refrigerant / source-reported GWPR-410A (GWP:2088)266 / 266
Compressor stagingTwo-stage266 / 266
Connected capabilityNo266 / 266

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC48FXXN1+TXV+ furnace: TL9E080C16UH11AHRI reference: 21035163415.208.10140002.10EPA 3987774
XAFC48FBAN1+ furnace: TL9E080C16UH11AHRI reference: 21035163815.208.10140002.10EPA 3987776
XAFC48FXXN1+TXV+ furnace: TL8E080C16UH11AHRI reference: 21035165415.207.80139002.08EPA 3987782
XAFC48FBAN1+ furnace: TL8E080C16UH11AHRI reference: 21035165815.207.80139002.08EPA 3987783
XAHC36DBAN1+ furnace: TL8E100C20UH11AHRI reference: 21035337915.207.80140002.10EPA 3987851
XAHC48FBAN1+ furnace: TL8E080C16UH11AHRI reference: 21036261415.207.80136002.02EPA 3988324
XAFA30DBAN1+ furnace: TL8E060A12UH11AHRI reference: 21036167415.207.80145002.14EPA 3988427
XAFC48FXXN1+TXV+ furnace: TM9Y080C16MP11AHRI reference: 21035054515.207.80141002.08EPA 3988502
XAFC48FBAN1+ furnace: TM9Y080C16MP11AHRI reference: 21035055115.207.80141002.08EPA 3988518
XAFB36DXXN1+TXV+ furnace: TM8V080B12MP12AHRI reference: 21035862615.207.80146002.12EPA 3988903
XAFB36DBAN1+ furnace: TM8V080B12MP12AHRI reference: 21035863515.207.80146002.12EPA 3988909
XAFB36DXXN1+TXV+ furnace: TM8V060A12MP12AHRI reference: 21035865315.207.80146002.08EPA 3988912
XAFB36DBAN1+ furnace: TM8V060A12MP12AHRI reference: 21035866515.207.80146002.08EPA 3988914
XAFB36DXXN1+TXV+ furnace: TL8E060A12UH11AHRI reference: 21035874515.207.80145002.12EPA 3988933
XAFB36DBAN1+ furnace: TL8E060A12UH11AHRI reference: 21035874915.207.80145002.12EPA 3988937
XAHB36DBAN1+ furnace: Z8ET080B12LMPS1AHRI reference: 21259429215.207.80145002.18EPA 3991212
XAFC48FBAN1+ furnace: Z9ET100C16SMPS1AHRI reference: 21637505515.208.10160002.34EPA 3992144
XAFC36DBAN1+ furnace: Z9ET100C16SMPS1AHRI reference: 21637505615.207.80154002.28EPA 3992145
XAFC36DBAN1+ furnace: Z9ET080C16SMPS1AHRI reference: 21637505715.207.80157002.28EPA 3992146
XAFB36DBAN1+ furnace: Z9ET060B12SMPS1AHRI reference: 21637506315.207.80156002.24EPA 3992147

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →