HMH72B341
HMH7 · source records, page 13
886 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 886 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 886 / 886 |
| EER2 · BTU/Wh | 9–10.5 | 886 / 886 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 886 / 886 |
| Cooling capacity · BTU/h | 31,400–35,200 | 886 / 886 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 886 / 886 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 886 / 886 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 886 / 886 |
| COP at 5°F / −15°C | 1.8–2.18 | 886 / 886 |
| Equipment / loop type | HP - Split System | 886 / 886 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 886 / 886 |
| Compressor staging | Continuously variable | 886 / 886 |
| Connected capability | No | 886 / 886 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFD48FBCN1+ furnace: TM8Y100C16MP11Cold climate designationAHRI reference: 211396858 | 17.50 | 8.50 | 24400 | 2.08 | EPA 2483033 → |
XAFD48FBCN1+ furnace: TM8Y080C16MP11Cold climate designationAHRI reference: 211396873 | 17.50 | 8.50 | 24400 | 2.08 | EPA 2483034 → |
XAFC48FXXN1+TXV+ furnace: TM8Y100C16MP11Cold climate designationAHRI reference: 211396888 | 17.50 | 8.50 | 24400 | 2.08 | EPA 2483037 → |
XAFC48FXXN1+TXV+ furnace: TM8Y080C16MP11Cold climate designationAHRI reference: 211396903 | 17.50 | 8.50 | 24400 | 2.08 | EPA 2483043 → |
XAFC48FBCN1+ furnace: TM8Y100C16MP11Cold climate designationAHRI reference: 211396918 | 17.50 | 8.50 | 24400 | 2.08 | EPA 2483049 → |
XAHC36DXXN1+TXV+ furnace: TM9Y060B12MP11Cold climate designationAHRI reference: 211387070 | 17.50 | 8.10 | 23600 | 2.00 | EPA 2483349 → |
XAFC36DXXN1+TXV+ furnace: TM9V100C20MP12Cold climate designationAHRI reference: 211387296 | 17.50 | 8.10 | 24800 | 2.12 | EPA 2483628 → |
XAFC36DXXN1+TXV+ furnace: CP9C100C20MP13Cold climate designationAHRI reference: 211387323 | 17.50 | 8.10 | 24800 | 2.12 | EPA 2483633 → |
XAFC36DBCN1+ furnace: TM9V100C20MP12Cold climate designationAHRI reference: 211387330 | 17.50 | 8.10 | 24800 | 2.12 | EPA 2483635 → |
XAFC30CXXN1+TXV+ furnace: TM9Y080B12MP11Cold climate designationAHRI reference: 211386987 | 17.50 | 8.10 | 23800 | 2.02 | EPA 2483645 → |
XAFB36DXXN1+TXV+ furnace: TM9Y080B12MP11Cold climate designationAHRI reference: 211387001 | 17.50 | 8.50 | 23600 | 2.04 | EPA 2483648 → |
XAFB36DBCN1+ furnace: TM9Y080B12MP11Cold climate designationAHRI reference: 211387015 | 17.50 | 8.50 | 23600 | 2.04 | EPA 2483912 → |
XAFB30CXXN1+TXV+ furnace: TM9Y080B12MP11Cold climate designationAHRI reference: 211387044 | 17.50 | 8.10 | 23800 | 2.02 | EPA 2483916 → |
XAFB36DXXN1+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211387871 | 17.50 | 8.50 | 23400 | 2.04 | EPA 2483935 → |
XAFB36DXXN1+TXV+ furnace: CP9C080B12MP13Cold climate designationAHRI reference: 211387901 | 17.50 | 8.50 | 23400 | 2.04 | EPA 2483938 → |
XAFC36DXXN1+TXV+ furnace: TL9E080C16UH11Cold climate designationAHRI reference: 211393091 | 17.50 | 8.10 | 24400 | 2.10 | EPA 2483966 → |
XAFB36DBCN1+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211387906 | 17.50 | 8.50 | 23400 | 2.04 | EPA 2484192 → |
XAFC36DXXN1+TXV+ furnace: TM9V100C16MP12Cold climate designationAHRI reference: 211387496 | 17.50 | 8.50 | 24000 | 2.10 | EPA 2484221 → |
XAFC36DBCN1+ furnace: TM9V100C16MP12Cold climate designationAHRI reference: 211387528 | 17.50 | 8.50 | 24000 | 2.10 | EPA 2484492 → |
XAFC36DBCN1+ furnace: TM9V060B12MP12Cold climate designationAHRI reference: 211388233 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2484512 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.