HH860E2S12
LX SERIES · source records, page 20
407 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11–12 | 407 / 407 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 43,500–54,000 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,000–53,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 40,000–45,500 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,600–40,000 | 407 / 407 |
| COP at 5°F / −15°C | 2–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60D5CGS2+ furnace: TM9E120D20MP12AHRI reference: 218689432 | 16.50 | 8.10 | 35000 | 2.24 | EPA 4677910 → |
CTM60D5CJS1+ furnace: Z9ES120D20SMPS1AHRI reference: 218699982 | 16.50 | 8.10 | 39000 | 2.24 | EPA 4685212 → |
CTF60D5CJS1+ furnace: Z9ES120D20SMPS1AHRI reference: 218699926 | 16.50 | 8.10 | 39000 | 2.24 | EPA 4685216 → |
CTM60D5CGS1+ furnace: TM9E120D20MP12AHRI reference: 218700754 | 16.50 | 8.10 | 35000 | 2.24 | EPA 4686160 → |
CTU60C5XGS1+TXV+ furnace: TM9E100C20MP12AHRI reference: 218700750 | 16.50 | 8.10 | 36200 | 2.26 | EPA 4686164 → |
CTF60C5CGS1+ furnace: TM9E100C20MP12AHRI reference: 218700746 | 16.50 | 8.10 | 36200 | 2.26 | EPA 4686168 → |
CTM60D5CGS1+ furnace: Z9ES120D20SMPS1AHRI reference: 218700714 | 16.50 | 8.10 | 35200 | 2.26 | EPA 4686200 → |
CTU60C5XGS1+TXV+ furnace: Z9ES100C16SMPS1AHRI reference: 218700654 | 16.50 | 8.10 | 34600 | 2.22 | EPA 4686260 → |
CTF60C5CGS1+ furnace: Z9ES100C16SMPS1AHRI reference: 218700650 | 16.50 | 8.10 | 34600 | 2.22 | EPA 4686264 → |
CTM60C5CGS1+ furnace: TM9E080C20MP12AHRI reference: 218700638 | 16.50 | 8.10 | 36200 | 2.26 | EPA 4686276 → |
CTF60D5CGS1+ furnace: TM9E120D20MP12AHRI reference: 218700578 | 16.50 | 8.10 | 35000 | 2.24 | EPA 4686336 → |
CTU60C5XGS1+TXV+ furnace: TM9E080C20MP12AHRI reference: 218700550 | 16.50 | 8.10 | 36200 | 2.26 | EPA 4686364 → |
CTF60C5CGS1+ furnace: TM9E080C20MP12AHRI reference: 218700546 | 16.50 | 8.10 | 36200 | 2.26 | EPA 4686368 → |
CTM60C5CGS1+ furnace: TM9E100C20MP12AHRI reference: 218700446 | 16.50 | 8.10 | 36200 | 2.26 | EPA 4686468 → |
CTF60D5CGS1+ furnace: Z9ES120D20SMPS1AHRI reference: 218700410 | 16.50 | 8.10 | 34200 | 2.24 | EPA 4686504 → |
CTF60D5CJS2+ furnace: TM9E120D20MP12AHRI reference: 218689431 | 16.00 | 8.10 | 39000 | 2.22 | EPA 4677911 → |
CTF60D5CJS1+ furnace: TM9E120D20MP12AHRI reference: 218700074 | 16.00 | 8.10 | 39000 | 2.22 | EPA 4685184 → |
CTF60D5CGS2AHRI reference: 218641994 | 15.20 | 8.10 | 35800 | 2.22 | EPA 4665711 → |
CTU60C5XGS2+TXVAHRI reference: 218641990 | 15.20 | 8.10 | 35800 | 2.22 | EPA 4665715 → |
CTF60C5CGS2AHRI reference: 218641986 | 15.20 | 8.10 | 35800 | 2.22 | EPA 4665719 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.