Coleman / AIR-SOURCE HEAT PUMP

HH860E2S12

LX SERIES · source records, page 17

407 published source records · source checked Sep 21, 2026

SEER2 range15.2–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity43,500–54,000BTU/h

Each efficiency range summarizes published EPA records for HH860E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–18407 / 407
EER2 · BTU/Wh11–12407 / 407
HSPF2 · BTU/Wh8.1–8.5407 / 407
Cooling capacity · BTU/h43,500–54,000407 / 407
Heating capacity at 47°F / 8.3°C · BTU/h44,000–53,500407 / 407
Heating capacity at 17°F / −8.3°C · BTU/h40,000–45,500407 / 407
Heating capacity at 5°F / −15°C · BTU/h33,600–40,000407 / 407
COP at 5°F / −15°C2–2.32407 / 407
Equipment / loop typeHP - Split System407 / 407
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)407 / 407
Compressor stagingTwo-stage407 / 407
Connected capabilityNo407 / 407

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60D5CGS1+ furnace: Z9ET120D20SMPS1AHRI reference: 21870015417.008.10344002.24EPA 4685160
CTM60C5CGS1+ furnace: Z9ES100C16SMPS1AHRI reference: 21870013817.008.10346002.22EPA 4685176
CTM60D5CJS1+ furnace: Z9ET120D20SMPS1AHRI reference: 21870007017.008.10390002.24EPA 4685188
CTM60D5CJS1+ furnace: Z8ES130D20LMPS1AHRI reference: 21870003417.008.10390002.28EPA 4685192
CTM60D5CJS1+ furnace: Z8ES130D20SMPS1AHRI reference: 21870003017.008.10390002.28EPA 4685196
CTF60D5CJS1+ furnace: Z9ET120D20SMPS1AHRI reference: 21870001817.008.10390002.26EPA 4685200
CTM60C5CGS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21870071817.008.10344002.24EPA 4686196
CTM60C5CGS1+ furnace: Z9ET100C20SMPS1AHRI reference: 21870071017.008.10350002.24EPA 4686204
CTU60C5XGS1+TXV+ furnace: Z8ET100C20LMPS1AHRI reference: 21870070617.008.10348002.26EPA 4686208
CTF60C5CGS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21870070217.008.10348002.26EPA 4686212
CTU60C5XGS1+TXV+ furnace: Z8ES100C20LMPS1AHRI reference: 21870069817.008.10348002.26EPA 4686216
CTU60C5XGS1+TXV+ furnace: Z8ES100C20SMPS1AHRI reference: 21870069417.008.10348002.26EPA 4686220
CTF60C5CGS1+ furnace: Z8ES100C20LMPS1AHRI reference: 21870069017.008.10348002.26EPA 4686224
CTF60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 21870068617.008.10348002.26EPA 4686228
CTU60C5XGS1+TXV+ furnace: TL8E100C20UH11AHRI reference: 21870064617.008.10350002.26EPA 4686268
CTF60C5CGS1+ furnace: TL8E100C20UH11AHRI reference: 21870064217.008.10350002.26EPA 4686272
CTU60C5XGS1+TXV+ furnace: CPLC100C16MP13AHRI reference: 21870063617.008.10340002.20EPA 4686278
CTU60C5XGS1+TXV+ furnace: CPLC080C16MP13AHRI reference: 21870063417.008.10340002.20EPA 4686280
CTU60C5XGS1+TXV+ furnace: TPLC100C16MP13AHRI reference: 21870063017.008.10340002.20EPA 4686284
CTU60C5XGS1+TXV+ furnace: TPLC080C16MP13AHRI reference: 21870062617.008.10340002.20EPA 4686288

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →