Heating performance & equipment details
Ranges include the 407 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–18 | 407 / 407 |
| EER2 · BTU/Wh | 11–12 | 407 / 407 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 407 / 407 |
| Cooling capacity · BTU/h | 43,500–54,000 | 407 / 407 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 44,000–53,500 | 407 / 407 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 40,000–45,500 | 407 / 407 |
| Heating capacity at 5°F / −15°C · BTU/h | 33,600–40,000 | 407 / 407 |
| COP at 5°F / −15°C | 2–2.32 | 407 / 407 |
| Equipment / loop type | HP - Split System | 407 / 407 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 407 / 407 |
| Compressor staging | Two-stage | 407 / 407 |
| Connected capability | No | 407 / 407 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CGS1+ furnace: TPLC100C16MP13AHRI reference: 218700538 | 17.50 | 8.10 | 33800 | 2.20 | EPA 4686376 → |
CTM60C5CGS1+ furnace: TPLC080C16MP13AHRI reference: 218700534 | 17.50 | 8.10 | 33800 | 2.20 | EPA 4686380 → |
CTM60C5CGS1+ furnace: TMLV100C16MP12AHRI reference: 218700530 | 17.50 | 8.10 | 33800 | 2.20 | EPA 4686384 → |
CTM60C5CGS1+ furnace: TM8V080C16MP12AHRI reference: 218700526 | 17.50 | 8.10 | 33800 | 2.20 | EPA 4686388 → |
CTM60C5CGS1+ furnace: TM8V100C16MP12AHRI reference: 218700522 | 17.50 | 8.10 | 33800 | 2.20 | EPA 4686392 → |
CTM60C5CGS1+ furnace: TM9E080C16MP12AHRI reference: 218700518 | 17.50 | 8.10 | 35200 | 2.20 | EPA 4686396 → |
CTM60C5CGS1+ furnace: TL8E100C20UH11AHRI reference: 218700514 | 17.50 | 8.10 | 35000 | 2.26 | EPA 4686400 → |
CTU60C5XGS1+TXV+ furnace: Z9ET100C16SMPS1AHRI reference: 218700510 | 17.50 | 8.10 | 35000 | 2.22 | EPA 4686404 → |
CTF60C5CGS1+ furnace: Z9ET100C16SMPS1AHRI reference: 218700506 | 17.50 | 8.10 | 35000 | 2.22 | EPA 4686408 → |
CTU60C5XGS1+TXV+ furnace: CPLC120C20MP13AHRI reference: 218700496 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4686418 → |
CTU60C5XGS1+TXV+ furnace: CPLC100C20MP13AHRI reference: 218700494 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4686420 → |
CTU60C5XGS1+TXV+ furnace: TPLC120C20MP13AHRI reference: 218700490 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4686424 → |
CTU60C5XGS1+TXV+ furnace: TPLC100C20MP13AHRI reference: 218700486 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4686428 → |
CTU60C5XGS1+TXV+ furnace: TMLV120C20MP12AHRI reference: 218700482 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4686432 → |
CTU60C5XGS1+TXV+ furnace: TM8V100C20MP12AHRI reference: 218700478 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4686436 → |
CTU60C5XGS1+TXV+ furnace: TM8V120C20MP12AHRI reference: 218700474 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4686440 → |
CTF60C5CGS1+ furnace: CPLC120C20MP13AHRI reference: 218700472 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4686442 → |
CTF60C5CGS1+ furnace: CPLC100C20MP13AHRI reference: 218700470 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4686444 → |
CTF60C5CGS1+ furnace: TPLC120C20MP13AHRI reference: 218700466 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4686448 → |
CTF60C5CGS1+ furnace: TPLC100C20MP13AHRI reference: 218700462 | 17.50 | 8.10 | 34000 | 2.20 | EPA 4686452 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.