Coleman / AIR-SOURCE HEAT PUMP

HH860E2S11

LX SERIES · source records, page 23

623 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity43,500–54,500BTU/h

Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 623 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19623 / 623
EER2 · BTU/Wh10–12623 / 623
HSPF2 · BTU/Wh8.1–9.5623 / 623
Cooling capacity · BTU/h43,500–54,500623 / 623
Heating capacity at 47°F / 8.3°C · BTU/h43,500–56,000623 / 623
Heating capacity at 17°F / −8.3°C · BTU/h31,800–39,000623 / 623
Heating capacity at 5°F / −15°C · BTU/h32,000–40,500623 / 623
COP at 5°F / −15°C2623 / 623
Equipment / loop typeHP - Split System623 / 623
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)623 / 623
Compressor stagingContinuously variable623 / 623
Connected capabilityNo623 / 623

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CGS2+ furnace: TL9E100C20UH11AHRI reference: 21852466618.009.00334002.00EPA 4645243 →
CTM60C5CGS2+ furnace: TM8V080C16MP12AHRI reference: 21852466218.009.00336002.00EPA 4645247 →
CTM60C5CGS2+ furnace: TM8V100C16MP12AHRI reference: 21852465818.009.00336002.00EPA 4645251 →
CTM60C5CGS2+ furnace: TL9E080C16UH11AHRI reference: 21852465418.009.00344002.00EPA 4645255 →
CTM60C5CGS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21852465018.009.00330002.00EPA 4645259 →
CTM60C5CGS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21852464618.009.00330002.00EPA 4645263 →
CTM60C5CGS2+ furnace: Z8ES080C16LMPS1AHRI reference: 21852464218.009.00334002.00EPA 4645267 →
CTM60C5CGS2+ furnace: Z8ES080C16SMPS1AHRI reference: 21852463818.009.00334002.00EPA 4645271 →
CTM60C5CGS2+ furnace: CP9C100C16MP13AHRI reference: 21852463618.009.00332002.00EPA 4645273 →
CTM60C5CGS2+ furnace: TP9C100C16MP13AHRI reference: 21852463218.009.00332002.00EPA 4645277 →
CTM60C5CGS2+ furnace: TM9V100C16MP12AHRI reference: 21852462818.009.00332002.00EPA 4645281 →
CTM60C5CGS2+ furnace: Z8ES100C20LMPS1AHRI reference: 21852462018.009.00334002.00EPA 4645289 →
CTM60C5CGS2+ furnace: Z8ES100C20SMPS1AHRI reference: 21852461618.009.00334002.00EPA 4645293 →
CTM60C5CGS2+ furnace: Z9ES100C16SMPS1AHRI reference: 21852461218.009.00338002.00EPA 4645297 →
CTM60C5CGS2+ furnace: Z9ET100C20SMPS1AHRI reference: 21852460818.009.00338002.00EPA 4645301 →
CTM60C5CGS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21852460018.009.00328002.00EPA 4645309 →
CTM60C5CGS2+ furnace: CP9C080C16MP13AHRI reference: 21852459818.009.00340002.00EPA 4645311 →
CTM60C5CGS2+ furnace: TP9C080C16MP13AHRI reference: 21852459418.009.00340002.00EPA 4645315 →
CTM60C5CGS2+ furnace: TM9V080C16MP12AHRI reference: 21852459018.009.00340002.00EPA 4645319 →
CTM60C5CGS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21852457818.009.00334002.00EPA 4645331 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →