Coleman / AIR-SOURCE HEAT PUMP

HH860E2S11

LX SERIES · source records, page 2

623 published source records · source checked Sep 21, 2026

SEER2 range15.2–19BTU/Wh
HSPF2 range8.1–9.5BTU/Wh
Cooling capacity43,500–54,500BTU/h

Each efficiency range summarizes published EPA records for HH860E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 623 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19623 / 623
EER2 · BTU/Wh10–12623 / 623
HSPF2 · BTU/Wh8.1–9.5623 / 623
Cooling capacity · BTU/h43,500–54,500623 / 623
Heating capacity at 47°F / 8.3°C · BTU/h43,500–56,000623 / 623
Heating capacity at 17°F / −8.3°C · BTU/h31,800–39,000623 / 623
Heating capacity at 5°F / −15°C · BTU/h32,000–40,500623 / 623
COP at 5°F / −15°C2623 / 623
Equipment / loop typeHP - Split System623 / 623
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)623 / 623
Compressor stagingContinuously variable623 / 623
Connected capabilityNo623 / 623

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CGS1+JMVT17CC2N1Cold climate designationAHRI reference: 21439790819.009.50338002.00EPA 3437764 →
CTF60C5CHS1+JME16C2SN1Cold climate designationAHRI reference: 21439842119.009.00385002.00EPA 3437803 →
CTM60C5CHS1+JMVT17CC2N1Cold climate designationAHRI reference: 21439842619.009.00380002.00EPA 3437807 →
CTF60C5CHS1+JMC17C2SN1Cold climate designationAHRI reference: 21439799719.009.00380002.00EPA 3437883 →
CTM60C5CGS1+JMC17C2SN1Cold climate designationAHRI reference: 21439832719.009.00334002.00EPA 3437890 →
CTM60D5CHS1+JMC20D2SN1Cold climate designationAHRI reference: 21439800719.008.50380002.00EPA 3437928 →
CTM60C5CGS1+JMVT16CC2N1Cold climate designationAHRI reference: 21439828519.009.00332002.00EPA 3437988 →
CTF60C5CGS1+JME16C2SN1Cold climate designationAHRI reference: 21439829019.009.00330002.00EPA 3437993 →
JHE48D5CG2SS1Cold climate designationAHRI reference: 21439863219.009.00334002.00EPA 3438037 →
CTM60C5CGS1+JMC16C2SN1Cold climate designationAHRI reference: 21439866619.009.00336002.00EPA 3438070 →
CTM60C5CGS1+JME16C2SN1Cold climate designationAHRI reference: 21439867119.009.00330002.00EPA 3438076 →
CTF60C5CHS1+ furnace: Z8ES120C20SMPS1Cold climate designationAHRI reference: 21458463119.009.00380002.00EPA 3438144 →
CTM60D5CHS1+ furnace: Z8ES130D20SMPS1Cold climate designationAHRI reference: 21458463619.009.00385002.00EPA 3438156 →
CTF60C5CHS1+ furnace: Z8ES100C20SMPS1Cold climate designationAHRI reference: 21458466619.009.00380002.00EPA 3438197 →
CTM60C5CHS1+ furnace: Z8ES120C20SMPS1Cold climate designationAHRI reference: 21458457619.009.00380002.00EPA 3438242 →
CTF60D5CHS1+ furnace: Z8ES130D20SMPS1Cold climate designationAHRI reference: 21458458119.009.00385002.00EPA 3438247 →
CTM60C5CHS1+ furnace: Z8ES100C20SMPS1Cold climate designationAHRI reference: 21458455119.009.00385002.00EPA 3438265 →
CTF60D5CHS1+ furnace: Z9ES120D20SMPS1Cold climate designationAHRI reference: 21460916519.008.50385002.00EPA 3473781 →
CTM60D5CHS1+ furnace: Z9ES120D20SMPS1Cold climate designationAHRI reference: 21460919519.008.50385002.00EPA 3473790 →
CTU60D5XHS1+TXV+ furnace: Z8ES130D20SMPS1Cold climate designationAHRI reference: 21465094419.009.00385002.00EPA 3477432 →