Heating performance & equipment details
Ranges include the 669 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–18 | 669 / 669 |
| EER2 · BTU/Wh | 10–11.7 | 669 / 669 |
| HSPF2 · BTU/Wh | 8.5 | 669 / 669 |
| Cooling capacity · BTU/h | 31,200–34,000 | 669 / 669 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,000–34,000 | 669 / 669 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 32,600–34,200 | 669 / 669 |
| Heating capacity at 5°F / −15°C · BTU/h | 26,800–28,200 | 669 / 669 |
| COP at 5°F / −15°C | 2.18–2.38 | 669 / 669 |
| Equipment / loop type | HP - Split System | 669 / 669 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 669 / 669 |
| Compressor staging | Two-stage | 669 / 669 |
| Connected capability | No | 669 / 669 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU36B5XDS1+TXV+ furnace: CPLC080B12MP13Cold climate designationAHRI reference: 218699258 | 16.50 | 8.50 | 27400 | 2.20 | EPA 4685692 → |
CTU36B5XDS1+TXV+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 218699254 | 16.50 | 8.50 | 27400 | 2.20 | EPA 4685696 → |
CTU36B5XDS1+TXV+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 218699250 | 16.50 | 8.50 | 27400 | 2.20 | EPA 4685700 → |
CTF36B5CDS1+ furnace: CPLC080B12MP13Cold climate designationAHRI reference: 218699248 | 16.50 | 8.50 | 27400 | 2.20 | EPA 4685702 → |
CTF36B5CDS1+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 218699244 | 16.50 | 8.50 | 27400 | 2.20 | EPA 4685706 → |
CTF36B5CDS1+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 218699240 | 16.50 | 8.50 | 27400 | 2.20 | EPA 4685710 → |
CTM36C5CDS1+ furnace: TL9E080C16UH11Cold climate designationAHRI reference: 218699236 | 16.50 | 8.50 | 28200 | 2.26 | EPA 4685714 → |
CTM36B5CDS1+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 218699216 | 16.50 | 8.50 | 27400 | 2.20 | EPA 4685734 → |
CTM36C5CDS1+ furnace: TL8E080C16UH11Cold climate designationAHRI reference: 218699156 | 16.50 | 8.50 | 28000 | 2.26 | EPA 4685786 → |
CTU48C5XFS1+TXV+ furnace: Z8ES120C20LMPS1Cold climate designationAHRI reference: 218699128 | 16.50 | 8.50 | 27200 | 2.32 | EPA 4685806 → |
CTU48C5XFS1+TXV+ furnace: Z8ES120C20SMPS1Cold climate designationAHRI reference: 218699124 | 16.50 | 8.50 | 27200 | 2.32 | EPA 4685810 → |
CTF48C5CFS1+ furnace: Z8ES120C20LMPS1Cold climate designationAHRI reference: 218699120 | 16.50 | 8.50 | 27200 | 2.32 | EPA 4685814 → |
CTF48C5CFS1+ furnace: Z8ES120C20SMPS1Cold climate designationAHRI reference: 218699116 | 16.50 | 8.50 | 27200 | 2.32 | EPA 4685818 → |
CTU48C5XFS1+TXV+ furnace: Z9ES080C20SMPS1Cold climate designationAHRI reference: 218699112 | 16.50 | 8.50 | 27200 | 2.32 | EPA 4685822 → |
CTF48C5CFS1+ furnace: Z9ES080C20SMPS1Cold climate designationAHRI reference: 218699108 | 16.50 | 8.50 | 27200 | 2.32 | EPA 4685826 → |
CTM48C5CFS1+ furnace: Z9ES080C20SMPS1Cold climate designationAHRI reference: 218699092 | 16.50 | 8.50 | 27200 | 2.32 | EPA 4685842 → |
CTU48C5XFS1+TXV+ furnace: Z9ES100C20SMPS1Cold climate designationAHRI reference: 218699076 | 16.50 | 8.50 | 27000 | 2.30 | EPA 4685858 → |
CTF48C5CFS1+ furnace: Z9ES100C20SMPS1Cold climate designationAHRI reference: 218699072 | 16.50 | 8.50 | 27000 | 2.30 | EPA 4685862 → |
CTM48C5CFS1+ furnace: Z8ES120C20LMPS1Cold climate designationAHRI reference: 218699020 | 16.50 | 8.50 | 27000 | 2.32 | EPA 4685914 → |
CTM48C5CFS1+ furnace: Z8ES120C20SMPS1Cold climate designationAHRI reference: 218699016 | 16.50 | 8.50 | 27000 | 2.32 | EPA 4685918 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.