Heating performance & equipment details
Ranges include the 669 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–18 | 669 / 669 |
| EER2 · BTU/Wh | 10–11.7 | 669 / 669 |
| HSPF2 · BTU/Wh | 8.5 | 669 / 669 |
| Cooling capacity · BTU/h | 31,200–34,000 | 669 / 669 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 32,000–34,000 | 669 / 669 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 32,600–34,200 | 669 / 669 |
| Heating capacity at 5°F / −15°C · BTU/h | 26,800–28,200 | 669 / 669 |
| COP at 5°F / −15°C | 2.18–2.38 | 669 / 669 |
| Equipment / loop type | HP - Split System | 669 / 669 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 669 / 669 |
| Compressor staging | Two-stage | 669 / 669 |
| Connected capability | No | 669 / 669 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM36C5CDS1+ furnace: Z8ES100C20LMPS1Cold climate designationAHRI reference: 218698884 | 17.00 | 8.50 | 27800 | 2.30 | EPA 4686050 → |
CTM36C5CDS1+ furnace: Z8ES100C20SMPS1Cold climate designationAHRI reference: 218698880 | 17.00 | 8.50 | 27800 | 2.30 | EPA 4686054 → |
CTU36B5XDS1+TXV+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 218698876 | 17.00 | 8.50 | 27800 | 2.24 | EPA 4686058 → |
CTF36B5CDS1+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 218698872 | 17.00 | 8.50 | 27800 | 2.24 | EPA 4686062 → |
CTU36B5XDS1+TXV+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 218698860 | 17.00 | 8.50 | 28000 | 2.26 | EPA 4686074 → |
CTF36B5CDS1+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 218698856 | 17.00 | 8.50 | 28000 | 2.26 | EPA 4686078 → |
CTF36C5CDS1+ furnace: Z8ES120C16LMPS1Cold climate designationAHRI reference: 218698852 | 17.00 | 8.50 | 27600 | 2.30 | EPA 4686082 → |
CTF36C5CDS1+ furnace: Z8ES120C16SMPS1Cold climate designationAHRI reference: 218698848 | 17.00 | 8.50 | 27600 | 2.30 | EPA 4686086 → |
CTM36B5CDS1+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 218698844 | 17.00 | 8.50 | 27800 | 2.26 | EPA 4686090 → |
CTM36B5CDS1+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 218698840 | 17.00 | 8.50 | 27800 | 2.26 | EPA 4686094 → |
CTF36C5CDS1+ furnace: Z9ES080C20SMPS1Cold climate designationAHRI reference: 218698836 | 17.00 | 8.50 | 28000 | 2.28 | EPA 4686098 → |
CTU36B5XDS1+TXV+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 218698832 | 17.00 | 8.50 | 27600 | 2.26 | EPA 4686102 → |
CTU36B5XDS1+TXV+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 218698828 | 17.00 | 8.50 | 27600 | 2.26 | EPA 4686106 → |
CTF36B5CDS1+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 218698824 | 17.00 | 8.50 | 27600 | 2.26 | EPA 4686110 → |
CTF36B5CDS1+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 218698820 | 17.00 | 8.50 | 27600 | 2.26 | EPA 4686114 → |
CTF36C5CDS1+ furnace: Z8ES100C20LMPS1Cold climate designationAHRI reference: 218698816 | 17.00 | 8.50 | 27800 | 2.32 | EPA 4686118 → |
CTF36C5CDS1+ furnace: Z8ES100C20SMPS1Cold climate designationAHRI reference: 218698812 | 17.00 | 8.50 | 27800 | 2.32 | EPA 4686122 → |
CTU36B5XDS1+TXV+ furnace: Z9ES080B12SMPS1Cold climate designationAHRI reference: 218698804 | 17.00 | 8.50 | 27600 | 2.24 | EPA 4686130 → |
CTF36B5CDS1+ furnace: Z9ES080B12SMPS1Cold climate designationAHRI reference: 218698800 | 17.00 | 8.50 | 27600 | 2.24 | EPA 4686134 → |
CTF36C5CDS1+ furnace: Z9ES080C16SMPS1Cold climate designationAHRI reference: 218698796 | 17.00 | 8.50 | 28200 | 2.28 | EPA 4686138 → |