HH836E2S11
LX SERIES · source records, page 11
927 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH836E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 927 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 927 / 927 |
| EER2 · BTU/Wh | 10–12 | 927 / 927 |
| HSPF2 · BTU/Wh | 8–9.5 | 927 / 927 |
| Cooling capacity · BTU/h | 31,600–35,000 | 927 / 927 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 30,000–33,400 | 927 / 927 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 25,400–29,600 | 927 / 927 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–27,200 | 927 / 927 |
| COP at 5°F / −15°C | 2–2.1 | 927 / 927 |
| Equipment / loop type | HP - Split System | 927 / 927 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 927 / 927 |
| Compressor staging | Continuously variable | 927 / 927 |
| Connected capability | No | 927 / 927 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF36C5CDS2+JMVT16CC2N1AHRI reference: 218522084 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4643492 → |
CTF36C5ADS2+JMVT16CC2N1AHRI reference: 218522080 | 19.00 | 9.00 | 25800 | 2.00 | EPA 4643496 → |
CTF36C5CDS2+JMC17C2SN1AHRI reference: 218521936 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4643640 → |
CTF36C5ADS2+JMC17C2SN1AHRI reference: 218521932 | 19.00 | 9.00 | 25400 | 2.00 | EPA 4643644 → |
CTF36C5CDS2+ furnace: Z8ES080C20LMPS1AHRI reference: 218521908 | 19.00 | 8.50 | 27000 | 2.00 | EPA 4643668 → |
CTF36C5CDS2+ furnace: Z8ES080C20SMPS1AHRI reference: 218521904 | 19.00 | 8.50 | 27000 | 2.00 | EPA 4643672 → |
CTF36C5ADS2+ furnace: Z8ES080C20LMPS1AHRI reference: 218521900 | 19.00 | 8.50 | 27000 | 2.00 | EPA 4643676 → |
CTF36C5ADS2+ furnace: Z8ES080C20SMPS1AHRI reference: 218521896 | 19.00 | 8.50 | 27000 | 2.00 | EPA 4643680 → |
CTF36C5CDS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218521852 | 19.00 | 9.00 | 22800 | 2.00 | EPA 4643724 → |
CTF36C5ADS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218521848 | 19.00 | 9.00 | 22800 | 2.00 | EPA 4643728 → |
CTF36C5CDS2+ furnace: Z8ET080C16LMPS1AHRI reference: 218521836 | 19.00 | 8.50 | 23400 | 2.00 | EPA 4643740 → |
CTF36C5ADS2+ furnace: Z8ET080C16LMPS1AHRI reference: 218521832 | 19.00 | 8.50 | 23400 | 2.00 | EPA 4643744 → |
CTF36C5CDS2+ furnace: Z8ET100C20LMPS1AHRI reference: 218521812 | 19.00 | 9.00 | 23200 | 2.00 | EPA 4643764 → |
CTF36C5ADS2+ furnace: Z8ET100C20LMPS1AHRI reference: 218521808 | 19.00 | 9.00 | 23200 | 2.00 | EPA 4643768 → |
CTF36C5CDS2+ furnace: Z8ET100C16LMPS1AHRI reference: 218521804 | 19.00 | 8.50 | 23800 | 2.00 | EPA 4643772 → |
CTF36C5ADS2+ furnace: Z8ET100C16LMPS1AHRI reference: 218521800 | 19.00 | 8.50 | 23800 | 2.00 | EPA 4643776 → |
CTM48C5CFS2+ furnace: Z8ET100C20LMPS1AHRI reference: 218521796 | 19.00 | 9.00 | 23000 | 2.00 | EPA 4643780 → |
CTM48C5CFS2+ furnace: Z8ET100C16LMPS1AHRI reference: 218521792 | 19.00 | 9.00 | 23200 | 2.00 | EPA 4643784 → |
CTM48C5CFS2+ furnace: Z8ET080C16LMPS1AHRI reference: 218521788 | 19.00 | 9.00 | 22800 | 2.00 | EPA 4643788 → |
CTM48C5CFS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218521784 | 19.00 | 9.00 | 22800 | 2.00 | EPA 4643792 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →