Coleman / AIR-SOURCE HEAT PUMP

HH824E2S12

LX SERIES · source records, page 9

264 published source records · source checked Sep 21, 2026

SEER2 range16–18BTU/Wh
HSPF2 range8.1–8.5BTU/Wh
Cooling capacity22,400–24,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S12. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 264 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh16–18264 / 264
EER2 · BTU/Wh11–12264 / 264
HSPF2 · BTU/Wh8.1–8.5264 / 264
Cooling capacity · BTU/h22,400–24,000264 / 264
Heating capacity at 47°F / 8.3°C · BTU/h22,000–24,000264 / 264
Heating capacity at 17°F / −8.3°C · BTU/h20,600–22,800264 / 264
Heating capacity at 5°F / −15°C · BTU/h17,200–18,700264 / 264
COP at 5°F / −15°C2.22–2.46264 / 264
Equipment / loop typeHP - Split System264 / 264
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)264 / 264
Compressor stagingTwo-stage264 / 264
Connected capabilityNo264 / 264

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF30B5ACS2+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 21869020616.508.50183002.30EPA 4679115
CTU30B5XCS2+TXV+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 21869020516.508.50179002.26EPA 4679116
CTF30B5ACS2+ furnace: CPLC080B12MP13Cold climate designationAHRI reference: 21869020416.508.50179002.26EPA 4679117
CTU30B5XCS2+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21869020116.508.50178002.26EPA 4679120
CTF30B5ACS2+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 21869020016.508.50178002.26EPA 4679121
CTF30B5ACS2+ furnace: TL9E060B12UH11Cold climate designationAHRI reference: 21869019816.508.50184002.28EPA 4679123
CTM30B5ACS2+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 21869019716.508.50180002.24EPA 4679124
CTM30B5ACS2+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21869019416.508.50178002.26EPA 4679127
CTU30B5XCS2+TXV+ furnace: TM9V060B12MP12AHRI reference: 21869016916.508.10174002.22EPA 4679150
CTF30B5ACS2+ furnace: TP9C060B12MP13AHRI reference: 21869016816.508.10174002.22EPA 4679151
CTM30B5ACS2+ furnace: CP9C060B12MP13Cold climate designationAHRI reference: 21869016716.508.50178002.24EPA 4679152
CTU30B5XCS2+TXV+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 21869016216.508.50179002.26EPA 4679157
CTF30B5ACS2+ furnace: TPLC080B12MP13Cold climate designationAHRI reference: 21869016116.508.50179002.26EPA 4679158
CTU30B5XCS2+TXV+ furnace: CP9C080B12MP13Cold climate designationAHRI reference: 21869016016.508.50178002.26EPA 4679159
CTF30B5ACS2+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 21869015716.508.50178002.26EPA 4679162
CTM30B5ACS2+ furnace: TM8V080B12MP12Cold climate designationAHRI reference: 21869015416.508.50180002.24EPA 4679165
CTM30B5ACS2+ furnace: CP9C080B12MP13Cold climate designationAHRI reference: 21869015316.508.50178002.26EPA 4679166
CTU30B5XCS2+TXV+ furnace: CP9C060B12MP13AHRI reference: 21869012616.508.10174002.22EPA 4679188
CTF30B5ACS2+ furnace: TM9V060B12MP12AHRI reference: 21869012316.508.10174002.22EPA 4679191
CTM30B5ACS2+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 21869012216.508.50178002.24EPA 4679192

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →