Heating performance & equipment details
Ranges include the 264 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 16–18 | 264 / 264 |
| EER2 · BTU/Wh | 11–12 | 264 / 264 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 264 / 264 |
| Cooling capacity · BTU/h | 22,400–24,000 | 264 / 264 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,000–24,000 | 264 / 264 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 20,600–22,800 | 264 / 264 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,200–18,700 | 264 / 264 |
| COP at 5°F / −15°C | 2.22–2.46 | 264 / 264 |
| Equipment / loop type | HP - Split System | 264 / 264 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 264 / 264 |
| Compressor staging | Two-stage | 264 / 264 |
| Connected capability | No | 264 / 264 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF30B5ACS2+ furnace: Z9ES080B12SMPS1Cold climate designationAHRI reference: 218643314 | 17.00 | 8.50 | 18200 | 2.30 | EPA 4666815 → |
CTU30B5XCS2+TXV+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 218643308 | 17.00 | 8.50 | 18100 | 2.32 | EPA 4666821 → |
CTU30B5XCS2+TXV+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 218643302 | 17.00 | 8.50 | 18100 | 2.32 | EPA 4666827 → |
CTF30B5ACS2+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 218643296 | 17.00 | 8.50 | 18100 | 2.32 | EPA 4666833 → |
CTF30B5ACS2+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 218643290 | 17.00 | 8.50 | 18100 | 2.32 | EPA 4666839 → |
CTM30B5ACS2+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 218643284 | 17.00 | 8.50 | 18100 | 2.30 | EPA 4666845 → |
CTM30B5ACS2+ furnace: Z8ES080B12SMPS1Cold climate designationAHRI reference: 218643278 | 17.00 | 8.50 | 18100 | 2.30 | EPA 4666851 → |
CTM30B5ACS2+JME12B2SN2Cold climate designationAHRI reference: 218643273 | 17.00 | 8.50 | 17500 | 2.26 | EPA 4666856 → |
CTU30B5XCS2+JME08B2SN2+TXVAHRI reference: 218643255 | 17.00 | 8.10 | 17200 | 2.24 | EPA 4666874 → |
CTF30B5ACS2+JME08B2SN2AHRI reference: 218643248 | 17.00 | 8.10 | 17200 | 2.24 | EPA 4666881 → |
CTM30B5ACS2+ furnace: Z8ET080B12LMPS1Cold climate designationAHRI reference: 218643242 | 17.00 | 8.50 | 18100 | 2.30 | EPA 4666887 → |
CTM30B5ACS2+JMC12B2SN1Cold climate designationAHRI reference: 218643230 | 17.00 | 8.50 | 18000 | 2.32 | EPA 4666899 → |
CTU30B5XCS2+TXV+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 218643212 | 17.00 | 8.50 | 18400 | 2.30 | EPA 4666917 → |
CTF30B5ACS2+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 218643206 | 17.00 | 8.50 | 18400 | 2.30 | EPA 4666923 → |
CTM30B5ACS2+JME08B2SN2AHRI reference: 218643194 | 17.00 | 8.10 | 17200 | 2.22 | EPA 4666935 → |
CTF36B5ADS2+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 218688910 | 17.00 | 8.50 | 18100 | 2.38 | EPA 4678361 → |
CTU36B5XDS2+TXV+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 218688909 | 17.00 | 8.50 | 18100 | 2.38 | EPA 4678362 → |
CTF36B5ADS2+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 218688899 | 17.00 | 8.50 | 18100 | 2.38 | EPA 4678372 → |
CTU36B5XDS2+TXV+ furnace: TP9C080B12MP13Cold climate designationAHRI reference: 218688898 | 17.00 | 8.50 | 18100 | 2.38 | EPA 4678373 → |
CTF36B5ADS2+ furnace: CP9C080B12MP13Cold climate designationAHRI reference: 218688889 | 17.00 | 8.50 | 18100 | 2.38 | EPA 4678382 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.