HH824E2S11
LX SERIES · source records, page 8
342 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HH824E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 342 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–19 | 342 / 342 |
| EER2 · BTU/Wh | 11–12 | 342 / 342 |
| HSPF2 · BTU/Wh | 8.5–9.5 | 342 / 342 |
| Cooling capacity · BTU/h | 23,000 | 342 / 342 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 23,000 | 342 / 342 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 17,100–18,900 | 342 / 342 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,200–19,400 | 342 / 342 |
| COP at 5°F / −15°C | 2 | 342 / 342 |
| Equipment / loop type | HP - Split System | 342 / 342 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 342 / 342 |
| Compressor staging | Continuously variable | 342 / 342 |
| Connected capability | No | 342 / 342 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF30B5ACS1+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 216783871 | 18.00 | 9.50 | 19100 | 2.00 | EPA 4008941 → |
CTF30A5ADS1+ furnace: Z8VT060A12SMPC1Cold climate designationAHRI reference: 217444050 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4044931 → |
CTM30B5ACS1+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 217444054 | 18.00 | 9.50 | 18200 | 2.00 | EPA 4044935 → |
CTF30B5ACS1+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 217444055 | 18.00 | 9.50 | 18200 | 2.00 | EPA 4044936 → |
CTU30B5XCS1+TXV+ furnace: Z8VT080B12SMPC1Cold climate designationAHRI reference: 217444056 | 18.00 | 9.50 | 18200 | 2.00 | EPA 4044938 → |
CTU30B5XCS1+TXV+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 216374544 | 18.00 | 9.50 | 18100 | 2.00 | EPA 4047593 → |
CTM36B5ADS1+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 216374564 | 18.00 | 9.50 | 18400 | 2.00 | EPA 4047604 → |
CTM30B5ACS1+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 216374585 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4047628 → |
CTM36B5ADS1+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 216374600 | 18.00 | 9.00 | 17400 | 2.00 | EPA 4047641 → |
CTF30B5ACS1+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 216374621 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4047661 → |
CTF36B5ADS1+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 216374641 | 18.00 | 9.50 | 18300 | 2.00 | EPA 4047675 → |
CTU30B5XCS1+TXV+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 216374661 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4047694 → |
CTM30B5ACS1+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 216374702 | 18.00 | 9.50 | 18100 | 2.00 | EPA 4047705 → |
CTF30B5ACS1+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 216374743 | 18.00 | 9.50 | 18100 | 2.00 | EPA 4047722 → |
CTU36B5XDS1+TXV+ furnace: Z9ET060B12SMPS1Cold climate designationAHRI reference: 216374681 | 18.00 | 9.50 | 18300 | 2.00 | EPA 4047732 → |
CTF36B5ADS1+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 216374722 | 18.00 | 9.50 | 17500 | 2.00 | EPA 4047754 → |
CTU36B5XDS1+TXV+ furnace: Z9ET080B12SMPS1Cold climate designationAHRI reference: 216374763 | 18.00 | 9.50 | 17500 | 2.00 | EPA 4047787 → |
CTM36B5ADS1+ furnace: Z8ES100B12LMPS1Cold climate designationAHRI reference: 216783514 | 18.00 | 9.50 | 18800 | 2.00 | EPA 4047872 → |
CTM36B5ADS1+ furnace: Z8ES080B12LMPS1Cold climate designationAHRI reference: 216785248 | 18.00 | 9.50 | 18600 | 2.00 | EPA 4047991 → |
CTM36B5ADS1+ furnace: Z8ES060A12SMPS1Cold climate designationAHRI reference: 216776009 | 18.00 | 9.50 | 18500 | 2.00 | EPA 4498322 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.