SEER2 range15.2–19BTU/Wh
HSPF2 range8.5–9.5BTU/Wh
Cooling capacity23,000BTU/h

Each efficiency range summarizes published EPA records for HH824E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 342 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–19342 / 342
EER2 · BTU/Wh11–12342 / 342
HSPF2 · BTU/Wh8.5–9.5342 / 342
Cooling capacity · BTU/h23,000342 / 342
Heating capacity at 47°F / 8.3°C · BTU/h23,000342 / 342
Heating capacity at 17°F / −8.3°C · BTU/h17,100–18,900342 / 342
Heating capacity at 5°F / −15°C · BTU/h17,200–19,400342 / 342
COP at 5°F / −15°C2342 / 342
Equipment / loop typeHP - Split System342 / 342
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)342 / 342
Compressor stagingContinuously variable342 / 342
Connected capabilityNo342 / 342

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36B5ADS2+ furnace: TP9C060B12MP13AHRI reference: 21852067617.009.00176002.00EPA 4642278
CTM36B5ADS2+ furnace: TM9V060B12MP12AHRI reference: 21852067217.009.00176002.00EPA 4642282
CTM36B5ADS2+ furnace: TM8V080B12MP12AHRI reference: 21852063017.009.00177002.00EPA 4642324
CTM30B5ACS2+ furnace: TM8V080B12MP12AHRI reference: 21852059417.009.50179002.00EPA 4642360
CTM30B5ACS2+ furnace: Z9ES060B12SMPS1AHRI reference: 21852059017.009.50192002.00EPA 4642364
CTM30B5ACS2+ furnace: TL9E060B12UH11AHRI reference: 21852058617.009.50183002.00EPA 4642368
CTM30B5ACS2+ furnace: CP9C080B12MP13AHRI reference: 21852057617.009.50178002.00EPA 4642378
CTM30B5ACS2+ furnace: TP9C080B12MP13AHRI reference: 21852057217.009.50178002.00EPA 4642382
CTM30B5ACS2+ furnace: TM9V080B12MP12AHRI reference: 21852056817.009.50178002.00EPA 4642386
CTM30B5ACS2+ furnace: CP9C060B12MP13AHRI reference: 21852056617.009.50180002.00EPA 4642388
CTM30B5ACS2+ furnace: TP9C060B12MP13AHRI reference: 21852056217.009.50180002.00EPA 4642392
CTM30B5ACS2+ furnace: TM9V060B12MP12AHRI reference: 21852055817.009.50180002.00EPA 4642396
CTU36B5XDS2+TXV+ furnace: Z9ES060B12SMPS1AHRI reference: 21852048617.009.50187002.00EPA 4642468
CTF36B5ADS2+ furnace: Z9ES060B12SMPS1AHRI reference: 21852048217.009.50187002.00EPA 4642472
CTU30B5XCS2+TXV+ furnace: CP9C080B12MP13AHRI reference: 21852036017.009.50182002.00EPA 4642594
CTU30B5XCS2+TXV+ furnace: TP9C080B12MP13AHRI reference: 21852035617.009.50182002.00EPA 4642598
CTU30B5XCS2+TXV+ furnace: TM9V080B12MP12AHRI reference: 21852035217.009.50182002.00EPA 4642602
CTF30B5ACS2+ furnace: CP9C080B12MP13AHRI reference: 21852035017.009.50182002.00EPA 4642604
CTF30B5ACS2+ furnace: TP9C080B12MP13AHRI reference: 21852034617.009.50182002.00EPA 4642608
CTF30B5ACS2+ furnace: TM9V080B12MP12AHRI reference: 21852034217.009.50182002.00EPA 4642612