HC19B6021
ECHELON
18 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HC19B6021. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 18 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 18 / 18 |
| EER2 · BTU/Wh | 11.7 | 18 / 18 |
| HSPF2 · BTU/Wh | 7.8 | 18 / 18 |
| Cooling capacity · BTU/h | 54,000–55,000 | 18 / 18 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 59,000–60,000 | 18 / 18 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 40,000–40,500 | 18 / 18 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,400–33,400 | 18 / 18 |
| COP at 5°F / −15°C | 2.08–2.28 | 18 / 18 |
| Equipment / loop type | HP - Split System | 18 / 18 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 18 / 18 |
| Compressor staging | Two-stage | 18 / 18 |
| Connected capability | No | 18 / 18 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHD60JBCN1+JMVT20DC2N1AHRI reference: 209375410 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624714 → |
XAFD60JBCN1+JMET18DS2N1AHRI reference: 210296168 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624722 → |
JHETD60JBCS2N1AHRI reference: 210296588 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624726 → |
XAFD60JBCN1+JMVT20DC2N1AHRI reference: 210297330 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624730 → |
XAFD60JBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 212487489 | 15.20 | 7.80 | 33400 | 2.28 | EPA 2476807 → |
XAHD60JBCN1+ furnace: Z8ES080C20LMPS1AHRI reference: 212480975 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2478127 → |
XAHD60JBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 212480970 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2478516 → |
XAHD60JBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 212489259 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2478888 → |
XAHD60JBCN1+ furnace: Z8ES120C20SMPS1AHRI reference: 212489254 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2479296 → |
XAFD60JBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 212487469 | 15.20 | 7.80 | 33400 | 2.28 | EPA 2480249 → |
XAHD60JBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 212480950 | 15.20 | 7.80 | 32600 | 2.22 | EPA 2480963 → |
XAHD60JBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 212480955 | 15.20 | 7.80 | 32600 | 2.22 | EPA 2484440 → |
XAHD60JBCN1+ furnace: Z8ES100C20SMPS1AHRI reference: 212476466 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2485934 → |
XAHD60JBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 212476471 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2485936 → |
XAHD60JBCN1+ furnace: TM9E080C20MP12AHRI reference: 209375350 | 15.20 | 7.80 | 32400 | 2.08 | EPA 3624710 → |
XAHD60JBCN1+JMET18DS2N1AHRI reference: 209375414 | 15.20 | 7.80 | 32400 | 2.16 | EPA 3624717 → |
XAHD60JBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 212594447 | 15.20 | 7.80 | 32600 | 2.14 | EPA 3991292 → |
XAHD60JBCN1+ furnace: Z8ET120C20LMPS1AHRI reference: 212594627 | 15.20 | 7.80 | 32600 | 2.14 | EPA 3991431 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →