XH660E2S11
LX SERIES · source records, page 2
222 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 222 / 222 |
| EER2 · BTU/Wh | 11–12 | 222 / 222 |
| HSPF2 · BTU/Wh | 7.8–8.5 | 222 / 222 |
| Cooling capacity · BTU/h | 52,500–55,000 | 222 / 222 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 56,000–60,000 | 222 / 222 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 37,800–39,500 | 222 / 222 |
| Heating capacity at 5°F / −15°C · BTU/h | 30,000–32,600 | 222 / 222 |
| COP at 5°F / −15°C | 2–2.38 | 222 / 222 |
| Equipment / loop type | HP - Split System | 222 / 222 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 222 / 222 |
| Compressor staging | Two-stage | 222 / 222 |
| Connected capability | No | 222 / 222 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
JHE60D5CJ2SS2AHRI reference: 218457236 | 16.00 | 8.50 | 32000 | 2.38 | EPA 4639450 → |
JHE60C5CH2SS2AHRI reference: 218457230 | 16.00 | 8.10 | 31400 | 2.28 | EPA 4639456 → |
CTM60D5CJS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218529072 | 16.00 | 8.10 | 32400 | 2.34 | EPA 4647050 → |
CTM60D5CJS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218529068 | 16.00 | 8.10 | 32400 | 2.34 | EPA 4647054 → |
CTM60D5CJS2+JMVT20DC2N1AHRI reference: 218529064 | 16.00 | 8.50 | 32000 | 2.36 | EPA 4647058 → |
CTM60D5CJS2+JMC20D2SN1AHRI reference: 218529060 | 16.00 | 8.50 | 32000 | 2.36 | EPA 4647062 → |
CTF60D5CJS2+ furnace: Z8ES130D20LMPS1AHRI reference: 218528824 | 16.00 | 8.50 | 32200 | 2.36 | EPA 4647286 → |
CTF60D5CJS2+ furnace: Z8ES130D20SMPS1AHRI reference: 218528820 | 16.00 | 8.50 | 32200 | 2.36 | EPA 4647290 → |
CTF60D5CJS2+JMC20D2SN1AHRI reference: 218528816 | 16.00 | 8.50 | 32000 | 2.38 | EPA 4647294 → |
CTF60D5CJS2+JMVT20DC2N1AHRI reference: 218528812 | 16.00 | 8.50 | 32000 | 2.38 | EPA 4647298 → |
CTF60D5CJS2+JME18D2SN2AHRI reference: 218638376 | 16.00 | 8.50 | 32000 | 2.36 | EPA 4664299 → |
CTM60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217445250 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4045310 → |
CTF60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217445251 | 15.20 | 8.10 | 31800 | 2.26 | EPA 4045311 → |
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445252 | 15.20 | 8.10 | 31800 | 2.26 | EPA 4045312 → |
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445253 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4045313 → |
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445254 | 15.20 | 8.10 | 32400 | 2.24 | EPA 4045314 → |
CTM60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445255 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4045315 → |
CTM60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217445257 | 15.20 | 8.10 | 31400 | 2.26 | EPA 4045317 → |
CTF60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217445256 | 15.20 | 8.10 | 31600 | 2.26 | EPA 4045318 → |
CTM60D5CJS1+ furnace: TP9C120D20MP13AHRI reference: 217994402 | 15.20 | 8.00 | 31400 | 2.00 | EPA 4570866 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →