CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH660E2S11

LX SERIES · source records, page 11

222 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.5BTU/Wh
Cooling capacity52,500–55,000BTU/h

Each efficiency range summarizes published EPA records for XH660E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 222 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16222 / 222
EER2 · BTU/Wh11–12222 / 222
HSPF2 · BTU/Wh7.8–8.5222 / 222
Cooling capacity · BTU/h52,500–55,000222 / 222
Heating capacity at 47°F / 8.3°C · BTU/h56,000–60,000222 / 222
Heating capacity at 17°F / −8.3°C · BTU/h37,800–39,500222 / 222
Heating capacity at 5°F / −15°C · BTU/h30,000–32,600222 / 222
COP at 5°F / −15°C2–2.38222 / 222
Equipment / loop typeHP - Split System222 / 222
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)222 / 222
Compressor stagingTwo-stage222 / 222
Connected capabilityNo222 / 222

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CHS2+ furnace: Z8ES100C16LMPS1AHRI reference: 21852865815.208.10316002.26EPA 4647434
CTF60C5CHS2+ furnace: Z8ES100C16SMPS1AHRI reference: 21852865415.208.10316002.26EPA 4647438
CTF60C5CHS2+ furnace: Z9ES100C16SMPS1AHRI reference: 21852864815.208.10316002.26EPA 4647444
CTF60C5CHS2+ furnace: Z8ET100C20LMPS1AHRI reference: 21852864415.208.10312002.28EPA 4647448
CTF60C5CHS2+JMC16C2SN1AHRI reference: 21852864015.208.10312002.28EPA 4647452
CTF60C5CHS2+JMVT16CC2N1AHRI reference: 21852863615.208.10312002.28EPA 4647456
CTF60C5CHS2+ furnace: Z9ET100C20SMPS1AHRI reference: 21852863215.208.10318002.24EPA 4647460
CTF60C5CHS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21852862615.208.10314002.26EPA 4647466
CTF60C5CHS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21852862215.208.10314002.26EPA 4647470
CTF60C5CHS2+JMC17C2SN1AHRI reference: 21852861815.208.10312002.28EPA 4647474
CTF60C5CHS2+JMVT17CC2N1AHRI reference: 21852861415.208.10312002.28EPA 4647478
CTF60C5CHS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21852860815.208.10316002.26EPA 4647484
CTF60C5CHS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21852860415.208.10316002.26EPA 4647488
CTF60C5CHS2+ furnace: Z8VT080C16SMPC1AHRI reference: 21852859415.208.10316002.26EPA 4647492
CTF60C5CHS2+ furnace: Z8VT100C20SMPC1AHRI reference: 21852859015.208.10316002.26EPA 4647496
CTF60C5CHS2+ furnace: Z8VT120C20SMPC1AHRI reference: 21852858615.208.10318002.26EPA 4647500
CTF60C5CHS2+ furnace: Z8VT100C16SMPC1AHRI reference: 21852858215.208.10318002.26EPA 4647504
CTM60D5CJS2+JME18D2SN2AHRI reference: 21863826215.208.50320002.36EPA 4664377
CTF60C5CHS2+JME16C2SN2AHRI reference: 21863825615.208.10314002.28EPA 4664383
CTM60D5CHS2+JME18D2SN2AHRI reference: 21863825015.208.10312002.30EPA 4664389

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →