CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH648E2S11

LX SERIES · source records, page 7

516 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity45,000–49,000BTU/h

Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 516 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16516 / 516
EER2 · BTU/Wh11.7–12516 / 516
HSPF2 · BTU/Wh7.8–8.1516 / 516
Cooling capacity · BTU/h45,000–49,000516 / 516
Heating capacity at 47°F / 8.3°C · BTU/h46,000–50,000516 / 516
Heating capacity at 17°F / −8.3°C · BTU/h31,800–34,000516 / 516
Heating capacity at 5°F / −15°C · BTU/h25,000–27,800516 / 516
COP at 5°F / −15°C2–2.4516 / 516
Equipment / loop typeHP - Split System516 / 516
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)516 / 516
Compressor stagingTwo-stage516 / 516
Connected capabilityNo516 / 516

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60C5CGS1+ furnace: Z9ET100C20SMPS1AHRI reference: 21702022716.008.10274002.22EPA 4015154
CTF60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21702022816.008.10276002.28EPA 4015155
CTM60C5CHS1+JME12C2SN1AHRI reference: 21702027216.008.10264002.36EPA 4015156
CTM60C5CHS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21702022916.008.10272002.30EPA 4015157
CTF60C5CGS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21702023116.008.10274002.22EPA 4015158
CTU60C5XGS1+TXV+ furnace: Z9ET100C16SMPS1AHRI reference: 21702023016.008.10274002.22EPA 4015159
CTU60C5XGS1+TXV+ furnace: Z8ES080C16SMPS1AHRI reference: 21702023316.008.10270002.26EPA 4015160
CTF60C5CGS1+ furnace: Z8ES080C16SMPS1AHRI reference: 21702023416.008.10270002.26EPA 4015161
CTF60C5CHS1+ furnace: Z8ES080C16SMPS1AHRI reference: 21702023516.008.10268002.34EPA 4015162
CTF60C5CGS1+JMVT16CC2N1AHRI reference: 21702024216.008.10272002.28EPA 4015163
CTF60C5CGS1+JMC17C2SN1AHRI reference: 21702024416.008.10272002.28EPA 4015164
CTU60C5XGS1+JMC17C2SN1+TXVAHRI reference: 21702024316.008.10272002.28EPA 4015165
CTM60D5CHS1+JMET18DS2N1AHRI reference: 21702024516.008.10268002.36EPA 4015166
CTF60C5CHS1+JME16C2SN1AHRI reference: 21702024716.008.10268002.36EPA 4015167
CTF60C5CHS1+JMET12CS2N1AHRI reference: 21702024616.008.10264002.34EPA 4015168
CTF60C5CHS1+JME12C2SN1AHRI reference: 21702024816.008.10264002.36EPA 4015169
CTU60D5XGS1+JME18D2SN1+TXVAHRI reference: 21702024916.008.10270002.30EPA 4015170
CTF60D5CGS1+JME18D2SN1AHRI reference: 21702025016.008.10270002.30EPA 4015171
CTF60C5CGS1+JMET12CS2N1AHRI reference: 21702025216.008.10268002.26EPA 4015173
CTU60C5XGS1+JMET16CS2N1+TXVAHRI reference: 21702025316.008.10274002.26EPA 4015174

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →