XH648E2S11
LX SERIES · source records, page 4
516 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 516 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 516 / 516 |
| EER2 · BTU/Wh | 11.7–12 | 516 / 516 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 516 / 516 |
| Cooling capacity · BTU/h | 45,000–49,000 | 516 / 516 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 516 / 516 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 516 / 516 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,000–27,800 | 516 / 516 |
| COP at 5°F / −15°C | 2–2.4 | 516 / 516 |
| Equipment / loop type | HP - Split System | 516 / 516 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 516 / 516 |
| Compressor staging | Two-stage | 516 / 516 |
| Connected capability | No | 516 / 516 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF60C5CHS1+ furnace: Z8ET080C16LMPS1AHRI reference: 217020189 | 16.00 | 8.10 | 26600 | 2.34 | EPA 4014667 → |
CTU60C5XGS1+TXV+ furnace: Z8ET100C16LMPS1AHRI reference: 217020192 | 16.00 | 8.10 | 27400 | 2.24 | EPA 4014668 → |
CTF60C5CGS1+ furnace: Z8ET100C16LMPS1AHRI reference: 217020193 | 16.00 | 8.10 | 27400 | 2.24 | EPA 4014669 → |
CTU60D5XHS1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 217020194 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014670 → |
CTF60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 217020195 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014671 → |
CTU60D5XGS1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 217020197 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4014672 → |
CTM60D5CHS1+ furnace: Z8ES130D20SMPS1AHRI reference: 217020196 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014673 → |
CTF60D5CGS1+ furnace: Z8ES130D20SMPS1AHRI reference: 217020198 | 16.00 | 8.10 | 27400 | 2.28 | EPA 4014674 → |
CTF60C5CGS1+ furnace: Z8ES120C20SMPS1AHRI reference: 217020200 | 16.00 | 8.10 | 27200 | 2.24 | EPA 4014675 → |
CTU60C5XGS1+TXV+ furnace: Z8ES120C20SMPS1AHRI reference: 217020199 | 16.00 | 8.10 | 27200 | 2.24 | EPA 4014676 → |
CTF60C5CHS1+ furnace: Z8ES120C20SMPS1AHRI reference: 217020201 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4014677 → |
CTM60C5CHS1+ furnace: Z8ES120C20SMPS1AHRI reference: 217020202 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4014678 → |
CTU60C5XGS1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 217020203 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4014679 → |
CTF60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 217020205 | 16.00 | 8.10 | 27200 | 2.34 | EPA 4014681 → |
CTF60C5CGS1+ furnace: Z8ES120C16SMPS1AHRI reference: 217020204 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4014682 → |
CTM60C5CHS1+ furnace: Z8ES120C16SMPS1AHRI reference: 217020206 | 16.00 | 8.10 | 27200 | 2.34 | EPA 4014683 → |
CTM60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 217020207 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4014684 → |
CTU60C5XGS1+TXV+ furnace: Z8ES100C20SMPS1AHRI reference: 217020208 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4014685 → |
CTF60C5CGS1+ furnace: Z8ES100C20SMPS1AHRI reference: 217020209 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4014686 → |
CTF60C5CHS1+ furnace: Z8ES100C20SMPS1AHRI reference: 217020210 | 16.00 | 8.10 | 27400 | 2.34 | EPA 4014687 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →