XH648E2S11
LX SERIES · source records, page 11
516 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH648E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 516 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 516 / 516 |
| EER2 · BTU/Wh | 11.7–12 | 516 / 516 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 516 / 516 |
| Cooling capacity · BTU/h | 45,000–49,000 | 516 / 516 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 46,000–50,000 | 516 / 516 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 31,800–34,000 | 516 / 516 |
| Heating capacity at 5°F / −15°C · BTU/h | 25,000–27,800 | 516 / 516 |
| COP at 5°F / −15°C | 2–2.4 | 516 / 516 |
| Equipment / loop type | HP - Split System | 516 / 516 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 516 / 516 |
| Compressor staging | Two-stage | 516 / 516 |
| Connected capability | No | 516 / 516 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM60C5CGS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217445233 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4045232 → |
CTF60C5CGS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445234 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4045233 → |
CTU60C5XGS1+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 217445235 | 16.00 | 8.10 | 27400 | 2.26 | EPA 4045234 → |
CTM60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445236 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4045235 → |
CTM60C5CGS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217445237 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4045236 → |
CTF60C5CGS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217445238 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4045237 → |
CTU60C5XGS1+TXV+ furnace: Z8VT080C16SMPC1AHRI reference: 217445239 | 16.00 | 8.10 | 27600 | 2.26 | EPA 4045238 → |
CTF60C5CGS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445240 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4045239 → |
CTU60C5XGS1+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 217445241 | 16.00 | 8.10 | 27200 | 2.26 | EPA 4045240 → |
CTM60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217445242 | 16.00 | 8.10 | 27400 | 2.34 | EPA 4045241 → |
CTM60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217445244 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4045242 → |
CTF60C5CHS1+ furnace: Z8VT100C16SMPC1AHRI reference: 217445243 | 16.00 | 8.10 | 27400 | 2.32 | EPA 4045243 → |
CTM60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445245 | 16.00 | 8.10 | 27000 | 2.34 | EPA 4045244 → |
CTM60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445246 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4045306 → |
CTF60C5CHS1+ furnace: Z8VT100C20SMPC1AHRI reference: 217445247 | 16.00 | 8.10 | 27000 | 2.34 | EPA 4045307 → |
CTF60C5CHS1+ furnace: Z8VT120C20SMPC1AHRI reference: 217445248 | 16.00 | 8.10 | 27000 | 2.36 | EPA 4045308 → |
CTF60C5CHS1+ furnace: Z8VT080C16SMPC1AHRI reference: 217445249 | 16.00 | 8.10 | 27400 | 2.34 | EPA 4045309 → |
JSC48D5CG2SS1AHRI reference: 217598332 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4497256 → |
JSE48D5CG2SS1AHRI reference: 217598333 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4497258 → |
JSC48C5CG2SS1AHRI reference: 217598338 | 16.00 | 8.10 | 27200 | 2.28 | EPA 4497261 → |