CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 9

454 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 454 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17454 / 454
EER2 · BTU/Wh11–12454 / 454
HSPF2 · BTU/Wh8–8.5454 / 454
Cooling capacity · BTU/h32,800–36,000454 / 454
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200454 / 454
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800454 / 454
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800454 / 454
COP at 5°F / −15°C2–2.5454 / 454
Equipment / loop typeHP - Split System454 / 454
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)454 / 454
Compressor stagingTwo-stage454 / 454
Connected capabilityNo454 / 454

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21701838316.008.10187002.34EPA 4013675 →
CTM48C5CFS1+ furnace: Z8ES080C20SMPS1AHRI reference: 21701838416.008.50193002.44EPA 4013676 →
CTM36C5CDS1+ furnace: Z8ES120C20SMPS1AHRI reference: 21701838516.008.10188002.32EPA 4013677 →
CTM36C5CDS1+ furnace: Z8ET080C16LMPS1AHRI reference: 21701838616.008.10188002.34EPA 4013678 →
CTM48C5CFS1+ furnace: Z8ET080C16LMPS1AHRI reference: 21701838716.008.50193002.44EPA 4013679 →
CTM36C5CDS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21701838816.008.10189002.34EPA 4013680 →
CTM48C5CFS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21701838916.008.50194002.44EPA 4013681 →
CTM36C5CDS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21701839016.008.10185002.36EPA 4013682 →
CTM48C5CFS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21701839116.008.50193002.44EPA 4013683 →
CTM48C5CFS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21701839216.008.10192002.44EPA 4013684 →
CTM36C5CDS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21701839316.008.10183002.34EPA 4013685 →
CTM36C5CDS1+ furnace: Z8ES080C16LMPS1AHRI reference: 21701839416.008.10188002.34EPA 4013686 →
CTM48C5CFS1+ furnace: Z8ES080C20LMPS1AHRI reference: 21701839616.008.50193002.44EPA 4013687 →
CTM36C5CDS1+ furnace: Z8ES080C20LMPS1AHRI reference: 21701839716.008.10187002.34EPA 4013688 →
CTM48C5CFS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21701839916.008.50195002.42EPA 4013689 →
CTM36C5CDS1+ furnace: Z8ES100C16LMPS1AHRI reference: 21701840016.008.10186002.34EPA 4013690 →
CTM36C5CDS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21701840316.008.10185002.36EPA 4013691 →
CTM48C5CFS1+ furnace: Z8ES120C16LMPS1AHRI reference: 21701840416.008.50190002.46EPA 4013692 →
CTM36C5CDS1+ furnace: Z8ES120C20LMPS1AHRI reference: 21701840516.008.10188002.32EPA 4013693 →
CTM48C5CFS1+ furnace: Z9ES080C16SMPS1AHRI reference: 21701840616.008.10191002.42EPA 4013694 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →