CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH636E2S11

LX SERIES · source records, page 22

454 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.5BTU/Wh
Cooling capacity32,800–36,000BTU/h

Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 454 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17454 / 454
EER2 · BTU/Wh11–12454 / 454
HSPF2 · BTU/Wh8–8.5454 / 454
Cooling capacity · BTU/h32,800–36,000454 / 454
Heating capacity at 47°F / 8.3°C · BTU/h34,000–36,200454 / 454
Heating capacity at 17°F / −8.3°C · BTU/h22,000–23,800454 / 454
Heating capacity at 5°F / −15°C · BTU/h17,600–19,800454 / 454
COP at 5°F / −15°C2–2.5454 / 454
Equipment / loop typeHP - Split System454 / 454
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)454 / 454
Compressor stagingTwo-stage454 / 454
Connected capabilityNo454 / 454

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS2+ furnace: TM9V100C20MP12AHRI reference: 21852734215.208.10180002.00EPA 4646838 →
CTM36C5CDS2+ furnace: TP9C080C16MP13AHRI reference: 21852733615.208.10180002.00EPA 4646844 →
CTM36C5CDS2+ furnace: TM9V080C16MP12AHRI reference: 21852733215.208.10180002.00EPA 4646848 →
CTM36C5CDS2+ furnace: TP9C100C16MP13AHRI reference: 21852732615.208.10180002.00EPA 4646854 →
CTM36C5CDS2+ furnace: TM9V100C16MP12AHRI reference: 21852732215.208.10180002.00EPA 4646858 →
CTU36B5XDS2+TXV+ furnace: TP9C060B12MP13AHRI reference: 21852731615.208.10180002.00EPA 4646864 →
CTU36B5XDS2+TXV+ furnace: TM9V060B12MP12AHRI reference: 21852731215.208.10180002.00EPA 4646868 →
CTF36B5CDS2+ furnace: TP9C060B12MP13AHRI reference: 21852730615.208.10180002.00EPA 4646874 →
CTU36B5XDS2+TXV+ furnace: TP9C080B12MP13AHRI reference: 21852729615.208.10180002.00EPA 4646878 →
CTU36B5XDS2+TXV+ furnace: TM9V080B12MP12AHRI reference: 21852729215.208.10180002.00EPA 4646882 →
CTF36B5CDS2+ furnace: TP9C080B12MP13AHRI reference: 21852728615.208.10180002.00EPA 4646888 →
CTF36B5CDS2+ furnace: TM9V080B12MP12AHRI reference: 21852728215.208.10180002.00EPA 4646892 →
CTF36B5CDS2+ furnace: Z9ES060B12SMPS1AHRI reference: 21852725015.208.10186002.28EPA 4646902 →
CTU36B5XDS2+TXV+ furnace: Z9ET080B12SMPS1AHRI reference: 21852724615.208.10187002.30EPA 4646906 →
CTF36B5CDS2+ furnace: Z9ET080B12SMPS1AHRI reference: 21852724215.208.10187002.30EPA 4646910 →
CTU36B5XDS2+TXV+ furnace: Z9ET060B12SMPS1AHRI reference: 21852721415.208.10184002.28EPA 4646938 →
CTF36B5CDS2+ furnace: Z9ET060B12SMPS1AHRI reference: 21852721015.208.10184002.28EPA 4646942 →
CTM36B5CDS2+ furnace: TP9C060B12MP13AHRI reference: 21852812415.208.10180002.00EPA 4647774 →
CTM36B5CDS2+ furnace: TM9V060B12MP12AHRI reference: 21852812015.208.10180002.00EPA 4647778 →
CTM36B5CDS2+ furnace: TP9C080B12MP13AHRI reference: 21852811415.208.10180002.00EPA 4647784 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.