XH636E2S11
LX SERIES · source records, page 2
454 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH636E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 454 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–17 | 454 / 454 |
| EER2 · BTU/Wh | 11–12 | 454 / 454 |
| HSPF2 · BTU/Wh | 8–8.5 | 454 / 454 |
| Cooling capacity · BTU/h | 32,800–36,000 | 454 / 454 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 34,000–36,200 | 454 / 454 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 22,000–23,800 | 454 / 454 |
| Heating capacity at 5°F / −15°C · BTU/h | 17,600–19,800 | 454 / 454 |
| COP at 5°F / −15°C | 2–2.5 | 454 / 454 |
| Equipment / loop type | HP - Split System | 454 / 454 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 454 / 454 |
| Compressor staging | Two-stage | 454 / 454 |
| Connected capability | No | 454 / 454 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTF48C5CFS1+JME16C2SN1AHRI reference: 217017414 | 17.00 | 8.10 | 18900 | 2.46 | EPA 4013213 → |
CTU48C5XFS1+JME16C2SN1+TXVAHRI reference: 217017415 | 17.00 | 8.10 | 18900 | 2.46 | EPA 4013214 → |
CTF48D5CFS1+JME18D2SN1AHRI reference: 217017416 | 17.00 | 8.50 | 19000 | 2.48 | EPA 4013215 → |
CTF48C5CFS1+JMC17C2SN1AHRI reference: 217017420 | 17.00 | 8.50 | 19100 | 2.46 | EPA 4013217 → |
CTU48C5XFS1+JMC17C2SN1+TXVAHRI reference: 217017421 | 17.00 | 8.50 | 19100 | 2.46 | EPA 4013218 → |
CTF48C5CFS1+JMVT16CC2N1AHRI reference: 217017422 | 17.00 | 8.50 | 19300 | 2.46 | EPA 4013219 → |
CTU48C5XFS1+JMVT16CC2N1+TXVAHRI reference: 217017423 | 17.00 | 8.50 | 19300 | 2.46 | EPA 4013221 → |
CTF48C5CFS1+JME12C2SN1AHRI reference: 217017428 | 17.00 | 8.50 | 19000 | 2.46 | EPA 4013226 → |
CTU48C5XFS1+TXV+ furnace: Z9ET080C16SMPS1AHRI reference: 217017433 | 17.00 | 8.10 | 19000 | 2.42 | EPA 4013229 → |
CTF48C5CFS1+ furnace: Z9ET080C16SMPS1AHRI reference: 217017435 | 17.00 | 8.10 | 19000 | 2.42 | EPA 4013231 → |
CTF48C5CFS1+ furnace: Z9ET100C16SMPS1AHRI reference: 217017437 | 17.00 | 8.10 | 19200 | 2.40 | EPA 4013233 → |
CTU48C5XFS1+TXV+ furnace: Z9ET100C16SMPS1AHRI reference: 217017438 | 17.00 | 8.10 | 19200 | 2.40 | EPA 4013234 → |
CTU48C5XFS1+JME12C2SN1+TXVAHRI reference: 217017439 | 17.00 | 8.50 | 19000 | 2.46 | EPA 4013235 → |
CTF48C5CFS1+ furnace: Z8ES080C20SMPS1AHRI reference: 217017444 | 17.00 | 8.50 | 19300 | 2.42 | EPA 4013239 → |
CTU48C5XFS1+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 217017445 | 17.00 | 8.50 | 19300 | 2.42 | EPA 4013240 → |
CTU48C5XFS1+TXV+ furnace: Z8ES100C16SMPS1AHRI reference: 217017449 | 17.00 | 8.50 | 19500 | 2.42 | EPA 4013245 → |
CTF48C5CFS1+ furnace: Z8ES100C16SMPS1AHRI reference: 217017450 | 17.00 | 8.50 | 19500 | 2.42 | EPA 4013247 → |
CTF48C5CFS1+ furnace: Z8ES120C16SMPS1AHRI reference: 217017452 | 17.00 | 8.50 | 19100 | 2.44 | EPA 4013248 → |
CTU48C5XFS1+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 217017453 | 17.00 | 8.50 | 19100 | 2.44 | EPA 4013249 → |
CTF48C5CFS1+ furnace: Z8ET080C16LMPS1AHRI reference: 217017458 | 17.00 | 8.50 | 19300 | 2.44 | EPA 4013255 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →