CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH630E2S11

LX SERIES · source records, page 7

219 published source records · source checked Sep 21, 2026

SEER2 range15.2–17BTU/Wh
HSPF2 range8–8.1BTU/Wh
Cooling capacity28,400–31,000BTU/h

Each efficiency range summarizes published EPA records for XH630E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 219 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–17219 / 219
EER2 · BTU/Wh11–13219 / 219
HSPF2 · BTU/Wh8–8.1219 / 219
Cooling capacity · BTU/h28,400–31,000219 / 219
Heating capacity at 47°F / 8.3°C · BTU/h28,800–30,000219 / 219
Heating capacity at 17°F / −8.3°C · BTU/h18,800–20,200219 / 219
Heating capacity at 5°F / −15°C · BTU/h15,000–16,400219 / 219
COP at 5°F / −15°C2–2.4219 / 219
Equipment / loop typeHP - Split System219 / 219
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)219 / 219
Compressor stagingTwo-stage219 / 219
Connected capabilityNo219 / 219

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5ADS2+ furnace: Z8ES080C20SMPS1AHRI reference: 21853045016.008.10152002.36EPA 4648422 →
CTM36C5ADS2+ furnace: TP9C080C16MP13AHRI reference: 21853044416.008.10156002.30EPA 4648428 →
CTM36C5ADS2+ furnace: TM9V080C16MP12AHRI reference: 21853044016.008.10156002.30EPA 4648432 →
CTM36C5ADS2+ furnace: TP9C100C16MP13AHRI reference: 21853043416.008.10156002.32EPA 4648438 →
CTM36C5ADS2+ furnace: TM9V100C16MP12AHRI reference: 21853043016.008.10156002.32EPA 4648442 →
CTM36C5ADS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21853040816.008.10154002.32EPA 4648458 →
CTM36C5ADS2+ furnace: Z8VT080C16SMPC1AHRI reference: 21853039016.008.10150002.40EPA 4648476 →
CTU36B5XDS2+TXV+ furnace: Z9ET060B12SMPS1AHRI reference: 21853038616.008.10158002.28EPA 4648480 →
CTF36B5ADS2+ furnace: Z9ET060B12SMPS1AHRI reference: 21853038216.008.10158002.28EPA 4648484 →
CTU36B5XDS2+TXV+ furnace: Z9ES060B12SMPS1AHRI reference: 21853037616.008.10158002.28EPA 4648490 →
CTF36B5ADS2+ furnace: Z9ES060B12SMPS1AHRI reference: 21853037016.008.10158002.28EPA 4648496 →
CTU36B5XDS2+TXV+ furnace: Z9ES080B12SMPS1AHRI reference: 21853036416.008.10158002.26EPA 4648502 →
CTF36B5ADS2+ furnace: Z9ES080B12SMPS1AHRI reference: 21853035816.008.10158002.26EPA 4648508 →
CTU36B5XDS2+TXV+ furnace: Z8VT080B12SMPC1AHRI reference: 21853035416.008.10150002.38EPA 4648512 →
CTF36B5ADS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21853035016.008.10150002.38EPA 4648516 →
CTU36B5XDS2+TXV+ furnace: TP9C080B12MP13AHRI reference: 21853033616.008.10156002.28EPA 4648530 →
CTU36B5XDS2+TXV+ furnace: TM9V080B12MP12AHRI reference: 21853033216.008.10156002.28EPA 4648534 →
CTF36B5ADS2+ furnace: TP9C080B12MP13AHRI reference: 21853032616.008.10156002.28EPA 4648540 →
CTF36B5ADS2+ furnace: TM9V080B12MP12AHRI reference: 21853032216.008.10156002.28EPA 4648544 →
CTU36B5XDS2+TXV+ furnace: Z8ES100B12LMPS1AHRI reference: 21853031616.008.10152002.36EPA 4648550 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →