CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH624E2S11

LX SERIES · source records, page 8

147 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,800–24,200BTU/h

Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 147 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16147 / 147
EER2 · BTU/Wh11.7–12147 / 147
HSPF2 · BTU/Wh7.8–8.1147 / 147
Cooling capacity · BTU/h22,800–24,200147 / 147
Heating capacity at 47°F / 8.3°C · BTU/h22,600–24,000147 / 147
Heating capacity at 17°F / −8.3°C · BTU/h14,500–15,500147 / 147
Heating capacity at 5°F / −15°C · BTU/h11,900–12,800147 / 147
COP at 5°F / −15°C2–2.3147 / 147
Equipment / loop typeHP - Split System147 / 147
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)147 / 147
Compressor stagingTwo-stage147 / 147
Connected capabilityNo147 / 147

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU36B5XDS2+TXV+ furnace: Z9ET060B12SMPS1AHRI reference: 21852828415.208.10126002.22EPA 4647728
CTF36B5ADS2+ furnace: Z9ET060B12SMPS1AHRI reference: 21852828015.208.10126002.22EPA 4647732
CTF30A5ADS2+ furnace: Z8VT060A12SMPC1AHRI reference: 21852813015.208.10125002.26EPA 4647768
CTM36B5ADS2+JME12B2SN2AHRI reference: 21863822615.208.00120002.24EPA 4664413
CTU36B5XDS2+JME08B2SN2+TXVAHRI reference: 21863821415.208.00119002.22EPA 4664425
CTF36B5ADS2+JME08B2SN2AHRI reference: 21863820815.208.00119002.22EPA 4664431
CTM36B5ADS2+JME08B2SN2AHRI reference: 21863816015.207.80119002.22EPA 4664455

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →