CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH624E2S11

LX SERIES · source records, page 5

147 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,800–24,200BTU/h

Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 147 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16147 / 147
EER2 · BTU/Wh11.7–12147 / 147
HSPF2 · BTU/Wh7.8–8.1147 / 147
Cooling capacity · BTU/h22,800–24,200147 / 147
Heating capacity at 47°F / 8.3°C · BTU/h22,600–24,000147 / 147
Heating capacity at 17°F / −8.3°C · BTU/h14,500–15,500147 / 147
Heating capacity at 5°F / −15°C · BTU/h11,900–12,800147 / 147
COP at 5°F / −15°C2–2.3147 / 147
Equipment / loop typeHP - Split System147 / 147
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)147 / 147
Compressor stagingTwo-stage147 / 147
Connected capabilityNo147 / 147

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF36B5ADS2+ furnace: Z8VT080B12SMPC1AHRI reference: 21852827216.008.10124002.28EPA 4647740 →
CTF30C5ACS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21852826216.007.80124002.10EPA 4647744 →
CTF30C5ACS2+ furnace: Z8ET120C20LMPS1AHRI reference: 21852825816.007.80123002.14EPA 4647748 →
CTU30B5XCS2+JMC12B2SN1+TXVAHRI reference: 21852821416.007.80122002.14EPA 4647752 →
CTF30B5ACS2+JMC12B2SN1AHRI reference: 21852821016.007.80122002.14EPA 4647756 →
CTU30B5XCS2+JMVT12BC2N1+TXVAHRI reference: 21852818616.007.80122002.14EPA 4647760 →
CTF30B5ACS2+JMVT12BC2N1AHRI reference: 21852818216.007.80122002.14EPA 4647764 →
CTF30C5ACS2+JME12C2SN2AHRI reference: 21863822016.007.80123002.14EPA 4664419 →
CTU36B5XDS2+JME12B2SN2+TXVAHRI reference: 21863818416.008.00120002.26EPA 4664437 →
CTF36B5ADS2+JME12B2SN2AHRI reference: 21863817816.008.00120002.26EPA 4664443 →
CTF30C5ACS2+JME16C2SN2AHRI reference: 21863817216.007.80123002.16EPA 4664449 →
CTF30A5ADS1+ furnace: Z8VT060A12SMPC1AHRI reference: 21744521615.208.10125002.26EPA 4045215 →
CTM36B5ADS1+ furnace: Z8VT080B12SMPC1AHRI reference: 21744521915.208.10124002.28EPA 4045217 →
CTF36C5ADS1+ furnace: TP9C100C16MP13AHRI reference: 21799361615.208.00120002.00EPA 4571087 →
CTM36C5ADS1+ furnace: TP9C100C16MP13AHRI reference: 21799361415.208.00120002.00EPA 4571089 →
CTM36B5ADS1+ furnace: TP9C080B12MP13AHRI reference: 21799361215.208.00120002.00EPA 4571091 →
CTU36B5XDS1+TXV+ furnace: TP9C080B12MP13AHRI reference: 21799361015.208.00120002.00EPA 4571093 →
CTF36B5ADS1+ furnace: TP9C080B12MP13AHRI reference: 21799360815.208.00120002.00EPA 4571095 →
CTF36C5ADS1+ furnace: TM9V100C16MP12AHRI reference: 21799359915.208.00120002.00EPA 4571098 →
CTM36C5ADS1+ furnace: TM9V100C16MP12AHRI reference: 21799359715.208.00120002.00EPA 4571100 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →