XH624E2S11
LX SERIES · source records, page 3
147 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 147 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 147 / 147 |
| EER2 · BTU/Wh | 11.7–12 | 147 / 147 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 147 / 147 |
| Cooling capacity · BTU/h | 22,800–24,200 | 147 / 147 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 22,600–24,000 | 147 / 147 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 14,500–15,500 | 147 / 147 |
| Heating capacity at 5°F / −15°C · BTU/h | 11,900–12,800 | 147 / 147 |
| COP at 5°F / −15°C | 2–2.3 | 147 / 147 |
| Equipment / loop type | HP - Split System | 147 / 147 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 147 / 147 |
| Compressor staging | Two-stage | 147 / 147 |
| Connected capability | No | 147 / 147 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 217017008 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572051 → |
CTF30C5ACS1+ furnace: Z8ET120C20LMPS1AHRI reference: 217016955 | 16.00 | 7.80 | 12300 | 2.14 | EPA 4572069 → |
CTF30C5ACS1+ furnace: Z9ET100C16SMPS1AHRI reference: 217016940 | 16.00 | 7.80 | 12400 | 2.10 | EPA 4572073 → |
CTF30C5ACS1+JMET12CS2N1AHRI reference: 217016913 | 16.00 | 7.80 | 12300 | 2.14 | EPA 4572081 → |
CTF30C5ACS1+JMET16CS2N1AHRI reference: 217016897 | 16.00 | 7.80 | 12300 | 2.16 | EPA 4572084 → |
CTF30B5ACS1+JME12B2SN1AHRI reference: 217016876 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572092 → |
CTU30B5XCS1+JMC12B2SN1+TXVAHRI reference: 217016846 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572097 → |
CTF30B5ACS1+JMC12B2SN1AHRI reference: 217016845 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572098 → |
CTU30B5XCS1+JMVT12BC2N1+TXVAHRI reference: 217016844 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572099 → |
CTF30B5ACS1+JMVT12BC2N1AHRI reference: 217016843 | 16.00 | 7.80 | 12200 | 2.14 | EPA 4572100 → |
CTF30C5ACS1+JME12C2SN1AHRI reference: 217016830 | 16.00 | 7.80 | 12200 | 2.16 | EPA 4572103 → |
CTF30C5ACS1+JME16C2SN1AHRI reference: 217016827 | 16.00 | 7.80 | 12200 | 2.16 | EPA 4572106 → |
JHE30B5AD2SS2AHRI reference: 218457224 | 16.00 | 8.10 | 12100 | 2.26 | EPA 4639462 → |
JHE24B5AC2SS2AHRI reference: 218457218 | 16.00 | 8.00 | 12000 | 2.12 | EPA 4639468 → |
CTM36B5ADS2+ furnace: Z8ES100B12LMPS1AHRI reference: 218528512 | 16.00 | 8.10 | 12500 | 2.26 | EPA 4647554 → |
CTM36B5ADS2+ furnace: Z8ES100B12SMPS1AHRI reference: 218528508 | 16.00 | 8.10 | 12500 | 2.26 | EPA 4647558 → |
CTM36B5ADS2+ furnace: Z8ET080B12LMPS1AHRI reference: 218528504 | 16.00 | 8.10 | 12400 | 2.26 | EPA 4647562 → |
CTM30B5ACS2+ furnace: Z8ES100B12LMPS1AHRI reference: 218528474 | 16.00 | 7.80 | 12500 | 2.10 | EPA 4647576 → |
CTM30B5ACS2+ furnace: Z8ES100B12SMPS1AHRI reference: 218528470 | 16.00 | 7.80 | 12500 | 2.10 | EPA 4647580 → |
CTM30B5ACS2+JMC12B2SN1AHRI reference: 218528456 | 16.00 | 7.80 | 12200 | 2.12 | EPA 4647584 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →