CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH624E2S11

LX SERIES · source records, page 3

147 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity22,800–24,200BTU/h

Each efficiency range summarizes published EPA records for XH624E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 147 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16147 / 147
EER2 · BTU/Wh11.7–12147 / 147
HSPF2 · BTU/Wh7.8–8.1147 / 147
Cooling capacity · BTU/h22,800–24,200147 / 147
Heating capacity at 47°F / 8.3°C · BTU/h22,600–24,000147 / 147
Heating capacity at 17°F / −8.3°C · BTU/h14,500–15,500147 / 147
Heating capacity at 5°F / −15°C · BTU/h11,900–12,800147 / 147
COP at 5°F / −15°C2–2.3147 / 147
Equipment / loop typeHP - Split System147 / 147
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)147 / 147
Compressor stagingTwo-stage147 / 147
Connected capabilityNo147 / 147

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 21701700816.007.80122002.14EPA 4572051
CTF30C5ACS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21701695516.007.80123002.14EPA 4572069
CTF30C5ACS1+ furnace: Z9ET100C16SMPS1AHRI reference: 21701694016.007.80124002.10EPA 4572073
CTF30C5ACS1+JMET12CS2N1AHRI reference: 21701691316.007.80123002.14EPA 4572081
CTF30C5ACS1+JMET16CS2N1AHRI reference: 21701689716.007.80123002.16EPA 4572084
CTF30B5ACS1+JME12B2SN1AHRI reference: 21701687616.007.80122002.14EPA 4572092
CTU30B5XCS1+JMC12B2SN1+TXVAHRI reference: 21701684616.007.80122002.14EPA 4572097
CTF30B5ACS1+JMC12B2SN1AHRI reference: 21701684516.007.80122002.14EPA 4572098
CTU30B5XCS1+JMVT12BC2N1+TXVAHRI reference: 21701684416.007.80122002.14EPA 4572099
CTF30B5ACS1+JMVT12BC2N1AHRI reference: 21701684316.007.80122002.14EPA 4572100
CTF30C5ACS1+JME12C2SN1AHRI reference: 21701683016.007.80122002.16EPA 4572103
CTF30C5ACS1+JME16C2SN1AHRI reference: 21701682716.007.80122002.16EPA 4572106
JHE30B5AD2SS2AHRI reference: 21845722416.008.10121002.26EPA 4639462
JHE24B5AC2SS2AHRI reference: 21845721816.008.00120002.12EPA 4639468
CTM36B5ADS2+ furnace: Z8ES100B12LMPS1AHRI reference: 21852851216.008.10125002.26EPA 4647554
CTM36B5ADS2+ furnace: Z8ES100B12SMPS1AHRI reference: 21852850816.008.10125002.26EPA 4647558
CTM36B5ADS2+ furnace: Z8ET080B12LMPS1AHRI reference: 21852850416.008.10124002.26EPA 4647562
CTM30B5ACS2+ furnace: Z8ES100B12LMPS1AHRI reference: 21852847416.007.80125002.10EPA 4647576
CTM30B5ACS2+ furnace: Z8ES100B12SMPS1AHRI reference: 21852847016.007.80125002.10EPA 4647580
CTM30B5ACS2+JMC12B2SN1AHRI reference: 21852845616.007.80122002.12EPA 4647584

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →