CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH618E2S11

LX SERIES · source records, page 7

272 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8BTU/Wh
Cooling capacity17,000–18,300BTU/h

Each efficiency range summarizes published EPA records for XH618E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 272 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16272 / 272
EER2 · BTU/Wh12–12.5272 / 272
HSPF2 · BTU/Wh7.8–8272 / 272
Cooling capacity · BTU/h17,000–18,300272 / 272
Heating capacity at 47°F / 8.3°C · BTU/h16,100–17,000272 / 272
Heating capacity at 17°F / −8.3°C · BTU/h10,700–11,300272 / 272
Heating capacity at 5°F / −15°C · BTU/h8,700–9,100272 / 272
COP at 5°F / −15°C2.26–2.34272 / 272
Equipment / loop typeHP - Split System272 / 272
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)272 / 272
Compressor stagingSingle stage272 / 272
Connected capabilityNo272 / 272

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF30B5ACS1+ furnace: Z9ET080B12SMPS1AHRI reference: 21841738415.207.8091002.30EPA 4609260 →
CTM30B5ACS1+ furnace: TP9C080B12MP13AHRI reference: 21841737815.207.8090002.28EPA 4609266 →
CTM30B5ACS1+ furnace: TM9V080B12MP12AHRI reference: 21841737415.207.8090002.28EPA 4609270 →
CTM30B5ACS1+ furnace: TMLE080B12MP11AHRI reference: 21841737015.207.8091002.28EPA 4609274 →
CTM30B5ACS1+ furnace: TM8E080B12MP11AHRI reference: 21841736615.207.8091002.28EPA 4609278 →
CTU30B5XCS1+TXV+ furnace: TL9E060B12UH11AHRI reference: 21841735215.207.8091002.26EPA 4609282 →
CTF30B5ACS1+ furnace: TL9E060B12UH11AHRI reference: 21841734815.207.8091002.26EPA 4609286 →
CTM30B5ACS1+ furnace: Z8ES080B12LMPS1AHRI reference: 21841734415.207.8088002.30EPA 4609290 →
CTM30B5ACS1+ furnace: Z8ES080B12SMPS1AHRI reference: 21841734015.207.8088002.30EPA 4609294 →
CTU30B5XCS1+TXV+ furnace: TM9Y080B12MP11AHRI reference: 21841732015.207.8088002.28EPA 4609298 →
CTF30B5ACS1+ furnace: TM9Y080B12MP11AHRI reference: 21841731615.207.8088002.28EPA 4609302 →
CTU30B5XCS1+TXV+ furnace: TMLE100B12MP11AHRI reference: 21841731215.207.8089002.28EPA 4609306 →
CTU30B5XCS1+TXV+ furnace: TM8E100B12MP11AHRI reference: 21841730815.207.8089002.28EPA 4609310 →
CTF30B5ACS1+ furnace: TMLE100B12MP11AHRI reference: 21841730415.207.8089002.28EPA 4609314 →
CTF30B5ACS1+ furnace: TM8E100B12MP11AHRI reference: 21841730015.207.8089002.28EPA 4609318 →
CTM30B5ACS1+ furnace: Z8ET080B12LMPS1AHRI reference: 21841729615.207.8088002.30EPA 4609322 →
CTM30B5ACS1+ furnace: TM9Y060B12MP11AHRI reference: 21841729215.207.8088002.28EPA 4609326 →
CTU30B5XCS1+TXV+ furnace: TM9Y060B12MP11AHRI reference: 21841728815.207.8091002.26EPA 4609330 →
CTF30B5ACS1+ furnace: TM9Y060B12MP11AHRI reference: 21841728415.207.8091002.26EPA 4609334 →
CTU30B5XCS1+TXV+ furnace: TMLE080B12MP11AHRI reference: 21841727615.207.8088002.28EPA 4609338 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →