XH618E2S11
LX SERIES · source records, page 2
272 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH618E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 272 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 272 / 272 |
| EER2 · BTU/Wh | 12–12.5 | 272 / 272 |
| HSPF2 · BTU/Wh | 7.8–8 | 272 / 272 |
| Cooling capacity · BTU/h | 17,000–18,300 | 272 / 272 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 16,100–17,000 | 272 / 272 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 10,700–11,300 | 272 / 272 |
| Heating capacity at 5°F / −15°C · BTU/h | 8,700–9,100 | 272 / 272 |
| COP at 5°F / −15°C | 2.26–2.34 | 272 / 272 |
| Equipment / loop type | HP - Split System | 272 / 272 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 272 / 272 |
| Compressor staging | Single stage | 272 / 272 |
| Connected capability | No | 272 / 272 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTM30B5ACS1+JME08B2SN1AHRI reference: 218417824 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4609000 → |
CTU30B5XCS1+JME12B2SN1+TXVAHRI reference: 218417812 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4609012 → |
CTF30B5ACS1+JME12B2SN1AHRI reference: 218417808 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4609016 → |
CTU30B5XCS1+JMET12BS2N1+TXVAHRI reference: 218417804 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4609020 → |
CTF30B5ACS1+JMET12BS2N1AHRI reference: 218417800 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4609024 → |
CTM30B5ACS1+JMET08BS2N1AHRI reference: 218417796 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4609028 → |
JHC18B5AB2SS1AHRI reference: 218417432 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4609220 → |
JHC24B5AC2SS1AHRI reference: 218417392 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4609252 → |
JHE18B5AB2SS1AHRI reference: 218417176 | 16.00 | 8.00 | 8800 | 2.30 | EPA 4609402 → |
CTU30B5XCS2+TXV+ furnace: Z8VT080B12SMPC1AHRI reference: 218530888 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4648092 → |
CTF30B5ACS2+ furnace: Z8VT080B12SMPC1AHRI reference: 218530884 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4648096 → |
CTU30B5XCS2+JMC12B2SN1+TXVAHRI reference: 218530880 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4648100 → |
CTF30B5ACS2+JMC12B2SN1AHRI reference: 218530876 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4648104 → |
CTF24B5ABS2+ furnace: Z8VT080B12SMPC1AHRI reference: 218530758 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4648174 → |
CTM30B5ACS2+JMC12B2SN1AHRI reference: 218531216 | 16.00 | 8.00 | 9000 | 2.32 | EPA 4649736 → |
CTM30B5ACS2+ furnace: Z8VT080B12SMPC1AHRI reference: 218531212 | 16.00 | 8.00 | 8900 | 2.34 | EPA 4649740 → |
CTM24B5ABS2+ furnace: Z8VT080B12SMPC1AHRI reference: 218531208 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4649744 → |
CTF24B5ABS2+JME12B2SN2AHRI reference: 218638442 | 16.00 | 8.00 | 8800 | 2.30 | EPA 4664233 → |
CTF24B5ABS2+JME08B2SN2AHRI reference: 218638438 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4664237 → |
CTM30B5ACS2+JME08B2SN2AHRI reference: 218638434 | 16.00 | 8.00 | 8900 | 2.32 | EPA 4664241 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →