CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 18

359 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16359 / 359
EER2 · BTU/Wh11–12359 / 359
HSPF2 · BTU/Wh7.8–8.1359 / 359
Cooling capacity · BTU/h44,500–48,000359 / 359
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000359 / 359
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400359 / 359
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200359 / 359
COP at 5°F / −15°C2.1–2.42359 / 359
Equipment / loop typeHP - Split System359 / 359
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)359 / 359
Compressor stagingTwo-stage359 / 359
Connected capabilityNo359 / 359

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTU60C5XGS2+JMVT16CC2N1+TXVAHRI reference: 21851707515.207.80250002.26EPA 4642138 →
CTF60C5CGS2+JMVT16CC2N1AHRI reference: 21851707115.207.80250002.26EPA 4642142 →
CTU60C5XGS2+JMC17C2SN1+TXVAHRI reference: 21851699515.207.80250002.26EPA 4642146 →
CTF60C5CGS2+JMC17C2SN1AHRI reference: 21851699115.207.80250002.26EPA 4642150 →
CTU60C5XGS2+JMVT17CC2N1+TXVAHRI reference: 21851698715.207.80250002.26EPA 4642154 →
CTF60C5CGS2+JMVT17CC2N1AHRI reference: 21851698315.207.80250002.26EPA 4642158 →
CTU60C5XGS2+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 21851696315.207.80260002.26EPA 4642162 →
CTF60C5CGS2+ furnace: Z8ET120C20LMPS1AHRI reference: 21851695915.207.80260002.26EPA 4642166 →
CTM60D5CGS2+JME18D2SN2AHRI reference: 21863696615.207.80254002.28EPA 4663807 →
CTF60D5CGS2+JME18D2SN2AHRI reference: 21863695815.207.80250002.26EPA 4663815 →
CTM60C5CHS2+JME12C2SN2AHRI reference: 21863695415.208.00258002.40EPA 4663819 →
CTF60C5CHS2+JME16C2SN2AHRI reference: 21863695015.208.10262002.38EPA 4663823 →
CTM60C5CGS2+JME16C2SN2AHRI reference: 21863693415.207.80256002.28EPA 4663827 →
CTU60C5XGS2+JME16C2SN2+TXVAHRI reference: 21863693015.207.80252002.24EPA 4663831 →
CTF60C5CGS2+JME16C2SN2AHRI reference: 21863692615.207.80252002.24EPA 4663835 →
CTM60C5CHS2+JME16C2SN2AHRI reference: 21863692215.208.10264002.40EPA 4663839 →
CTF60D5CHS2+JME18D2SN2AHRI reference: 21863691415.208.10260002.40EPA 4663847 →
CTM60D5CHS2+JME18D2SN2AHRI reference: 21863691015.208.10262002.42EPA 4663851 →
CTF60C5CHS2+JME12C2SN2AHRI reference: 21863690615.207.80258002.40EPA 4663855 →