XH548E2S11
LX SERIES · source records, page 18
359 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 359 / 359 |
| EER2 · BTU/Wh | 11–12 | 359 / 359 |
| HSPF2 · BTU/Wh | 7.8–8.1 | 359 / 359 |
| Cooling capacity · BTU/h | 44,500–48,000 | 359 / 359 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 45,000–48,000 | 359 / 359 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 29,200–32,400 | 359 / 359 |
| Heating capacity at 5°F / −15°C · BTU/h | 24,600–27,200 | 359 / 359 |
| COP at 5°F / −15°C | 2.1–2.42 | 359 / 359 |
| Equipment / loop type | HP - Split System | 359 / 359 |
| Refrigerant / source-reported GWP | R-454B (GWP:470 | Lower GWP) | 359 / 359 |
| Compressor staging | Two-stage | 359 / 359 |
| Connected capability | No | 359 / 359 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
CTU60C5XGS2+JMVT16CC2N1+TXVAHRI reference: 218517075 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4642138 → |
CTF60C5CGS2+JMVT16CC2N1AHRI reference: 218517071 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4642142 → |
CTU60C5XGS2+JMC17C2SN1+TXVAHRI reference: 218516995 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4642146 → |
CTF60C5CGS2+JMC17C2SN1AHRI reference: 218516991 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4642150 → |
CTU60C5XGS2+JMVT17CC2N1+TXVAHRI reference: 218516987 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4642154 → |
CTF60C5CGS2+JMVT17CC2N1AHRI reference: 218516983 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4642158 → |
CTU60C5XGS2+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 218516963 | 15.20 | 7.80 | 26000 | 2.26 | EPA 4642162 → |
CTF60C5CGS2+ furnace: Z8ET120C20LMPS1AHRI reference: 218516959 | 15.20 | 7.80 | 26000 | 2.26 | EPA 4642166 → |
CTM60D5CGS2+JME18D2SN2AHRI reference: 218636966 | 15.20 | 7.80 | 25400 | 2.28 | EPA 4663807 → |
CTF60D5CGS2+JME18D2SN2AHRI reference: 218636958 | 15.20 | 7.80 | 25000 | 2.26 | EPA 4663815 → |
CTM60C5CHS2+JME12C2SN2AHRI reference: 218636954 | 15.20 | 8.00 | 25800 | 2.40 | EPA 4663819 → |
CTF60C5CHS2+JME16C2SN2AHRI reference: 218636950 | 15.20 | 8.10 | 26200 | 2.38 | EPA 4663823 → |
CTM60C5CGS2+JME16C2SN2AHRI reference: 218636934 | 15.20 | 7.80 | 25600 | 2.28 | EPA 4663827 → |
CTU60C5XGS2+JME16C2SN2+TXVAHRI reference: 218636930 | 15.20 | 7.80 | 25200 | 2.24 | EPA 4663831 → |
CTF60C5CGS2+JME16C2SN2AHRI reference: 218636926 | 15.20 | 7.80 | 25200 | 2.24 | EPA 4663835 → |
CTM60C5CHS2+JME16C2SN2AHRI reference: 218636922 | 15.20 | 8.10 | 26400 | 2.40 | EPA 4663839 → |
CTF60D5CHS2+JME18D2SN2AHRI reference: 218636914 | 15.20 | 8.10 | 26000 | 2.40 | EPA 4663847 → |
CTM60D5CHS2+JME18D2SN2AHRI reference: 218636910 | 15.20 | 8.10 | 26200 | 2.42 | EPA 4663851 → |
CTF60C5CHS2+JME12C2SN2AHRI reference: 218636906 | 15.20 | 7.80 | 25800 | 2.40 | EPA 4663855 → |