CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 15

359 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16359 / 359
EER2 · BTU/Wh11–12359 / 359
HSPF2 · BTU/Wh7.8–8.1359 / 359
Cooling capacity · BTU/h44,500–48,000359 / 359
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000359 / 359
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400359 / 359
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200359 / 359
COP at 5°F / −15°C2.1–2.42359 / 359
Equipment / loop typeHP - Split System359 / 359
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)359 / 359
Compressor stagingTwo-stage359 / 359
Connected capabilityNo359 / 359

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF60D5CHS2+ furnace: Z9ET120D20SMPS1AHRI reference: 21851759315.207.80260002.38EPA 4641842
CTF60D5CHS2+ furnace: Z8ES130D20LMPS1AHRI reference: 21851758115.208.10266002.38EPA 4641854
CTF60D5CHS2+ furnace: Z8ES130D20SMPS1AHRI reference: 21851757715.208.10266002.38EPA 4641858
CTF60D5CHS2+JMC20D2SN1AHRI reference: 21851756915.208.10262002.42EPA 4641866
CTF60D5CHS2+JMVT20DC2N1AHRI reference: 21851756115.208.10262002.42EPA 4641874
CTF60D5CHS2+ furnace: TP9C120D20MP13AHRI reference: 21851754515.207.80268002.34EPA 4641890
CTF60D5CHS2+ furnace: TM9V120D20MP12AHRI reference: 21851754115.207.80268002.34EPA 4641894
CTF60D5CHS2+ furnace: Z9ES120D20SMPS1AHRI reference: 21851753315.207.80258002.38EPA 4641902
CTF60D5CGS2+JMC20D2SN1AHRI reference: 21851751715.207.80246002.28EPA 4641910
CTF60D5CGS2+ furnace: Z8ES130D20LMPS1AHRI reference: 21851748515.207.80254002.24EPA 4641922
CTF60D5CGS2+ furnace: Z8ES130D20SMPS1AHRI reference: 21851748115.207.80254002.24EPA 4641926
CTF60D5CGS2+JMVT20DC2N1AHRI reference: 21851747315.207.80246002.28EPA 4641934
CTF60D5CGS2+ furnace: Z9ET120D20SMPS1AHRI reference: 21851746515.207.80258002.26EPA 4641942
CTF60C5CHS2+ furnace: Z9ET080C16SMPS1AHRI reference: 21851746115.207.80262002.34EPA 4641946
CTF60C5CHS2+ furnace: Z9ET100C20SMPS1AHRI reference: 21851745715.207.80264002.34EPA 4641950
CTF60C5CHS2+ furnace: Z9ET100C16SMPS1AHRI reference: 21851745315.207.80266002.34EPA 4641954
CTF60C5CHS2+ furnace: Z8ET100C16LMPS1AHRI reference: 21851744915.207.80260002.40EPA 4641958
CTF60C5CHS2+ furnace: Z8ET100C20LMPS1AHRI reference: 21851744515.207.80262002.38EPA 4641962
CTF60C5CHS2+ furnace: Z8ET120C20LMPS1AHRI reference: 21851744115.207.80260002.40EPA 4641966
CTF60C5CHS2+ furnace: Z8ES080C16LMPS1AHRI reference: 21851743715.207.80262002.36EPA 4641970