CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH548E2S11

LX SERIES · source records, page 11

359 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–48,000BTU/h

Each efficiency range summarizes published EPA records for XH548E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 359 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16359 / 359
EER2 · BTU/Wh11–12359 / 359
HSPF2 · BTU/Wh7.8–8.1359 / 359
Cooling capacity · BTU/h44,500–48,000359 / 359
Heating capacity at 47°F / 8.3°C · BTU/h45,000–48,000359 / 359
Heating capacity at 17°F / −8.3°C · BTU/h29,200–32,400359 / 359
Heating capacity at 5°F / −15°C · BTU/h24,600–27,200359 / 359
COP at 5°F / −15°C2.1–2.42359 / 359
Equipment / loop typeHP - Split System359 / 359
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)359 / 359
Compressor stagingTwo-stage359 / 359
Connected capabilityNo359 / 359

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM60C5CGS1+JMVT16CC2N1AHRI reference: 21442860815.207.80256002.28EPA 4572436
CTF60C5CGS1+JMC17C2SN1AHRI reference: 21442836915.207.80250002.26EPA 4572441
CTF60D5CHS1+ furnace: TP9C120D20MP13AHRI reference: 21442833215.207.80268002.34EPA 4572463
CTF60D5CHS1+ furnace: TM9V120D20MP12AHRI reference: 21442832715.207.80268002.34EPA 4572468
CTM60C5CHS1+ furnace: TM8V080C16MP12AHRI reference: 21442802715.207.80264002.34EPA 4572483
CTM60C5CHS1+ furnace: TM8V100C16MP12AHRI reference: 21442802215.207.80264002.34EPA 4572488
CTM60C5CHS1+ furnace: TL9E080C16UH11AHRI reference: 21442777815.207.80268002.30EPA 4572498
CTF60C5CGS1+JMC16C2SN1AHRI reference: 21442743215.207.80250002.26EPA 4572503
CTF60C5CGS1+JMVT16CC2N1AHRI reference: 21442742715.207.80250002.26EPA 4572508
CTF60C5CGS1+JMVT17CC2N1AHRI reference: 21442741715.207.80250002.26EPA 4572513
JHE60C5CH2SS2AHRI reference: 21845699815.208.10264002.40EPA 4639516
JHE48C5CG2SS2AHRI reference: 21845699415.207.80248002.10EPA 4639520
JHE60D5CH2SS2AHRI reference: 21845699015.208.10262002.42EPA 4639524
JHE48D5CG2SS2AHRI reference: 21845698615.207.80246002.26EPA 4639528
CTM60D5CHS2+JMC20D2SN1AHRI reference: 21851802915.208.10262002.42EPA 4641552
CTM60D5CHS2+ furnace: Z8ES130D20LMPS1AHRI reference: 21851802515.208.10264002.40EPA 4641556
CTM60D5CHS2+ furnace: Z8ES130D20SMPS1AHRI reference: 21851802115.208.10264002.40EPA 4641560
CTM60D5CHS2+ furnace: Z9ET120D20SMPS1AHRI reference: 21851801715.208.00266002.36EPA 4641564
CTM60D5CHS2+JMVT20DC2N1AHRI reference: 21851801315.208.10262002.42EPA 4641568
CTM60D5CHS2+ furnace: TP9C120D20MP13AHRI reference: 21851800715.207.80262002.36EPA 4641574

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →