CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES · source records, page 5

273 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 273 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16273 / 273
EER2 · BTU/Wh10–12273 / 273
HSPF2 · BTU/Wh7.8–8.1273 / 273
Cooling capacity · BTU/h32,400–35,000273 / 273
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800273 / 273
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000273 / 273
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400273 / 273
COP at 5°F / −15°C2–2.44273 / 273
Equipment / loop typeHP - Split System273 / 273
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)273 / 273
Compressor stagingTwo-stage273 / 273
Connected capabilityNo273 / 273

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM48C5CFS1+ furnace: Z8ET100C20LMPS1AHRI reference: 21643778915.208.10179002.40EPA 3815033
CTM48D5CFS1+JME18D2SN1AHRI reference: 21643779415.208.10176002.42EPA 3815039
CTM48C5CFS1+ furnace: Z8ET080C16LMPS1AHRI reference: 21643780415.208.10180002.38EPA 3815043
CTM48C5CFS1+ furnace: Z8ET100C16LMPS1AHRI reference: 21643781415.208.10180002.38EPA 3815048
CTM48C5CFS1+ furnace: Z8ET120C20LMPS1AHRI reference: 21643781915.208.10181002.38EPA 3815053
CTM36C5CDS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744479615.208.10184002.40EPA 4044965
CTF36C5CDS1+ furnace: Z8VT080C16SMPC1AHRI reference: 21744479815.208.10184002.40EPA 4044966
CTM36C5CDS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744479715.208.10184002.40EPA 4044967
CTF36C5CDS1+ furnace: Z8VT100C16SMPC1AHRI reference: 21744479915.208.10184002.40EPA 4044968
CTM48C5CFS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744480615.208.10178002.40EPA 4044975
CTF48C5CFS1+ furnace: Z8VT100C20SMPC1AHRI reference: 21744480815.208.10178002.40EPA 4044976
CTM48C5CFS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744480715.208.10177002.42EPA 4044977
CTU48C5XFS1+TXV+ furnace: Z8VT100C20SMPC1AHRI reference: 21744480915.208.10178002.40EPA 4044978
CTF48C5CFS1+ furnace: Z8VT120C20SMPC1AHRI reference: 21744481015.208.10177002.42EPA 4044979
CTU48C5XFS1+TXV+ furnace: Z8VT120C20SMPC1AHRI reference: 21744481115.208.10177002.42EPA 4044980
CTF36C5CDS1+JMET12CS2N1AHRI reference: 21443155615.208.10176002.00EPA 4046799
CTM48C5CFS1+ furnace: TM8V120C20MP12AHRI reference: 21443133515.208.10180002.00EPA 4046807
CTM48C5CFS1+ furnace: TM8V100C20MP12AHRI reference: 21443134015.208.10180002.00EPA 4046811
CTM48C5CFS1+ furnace: TMLV120C20MP12AHRI reference: 21443134515.208.10180002.00EPA 4046817
CTM48C5CFS1+ furnace: TM9V100C16MP12AHRI reference: 21443137615.208.10180002.00EPA 4046820

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →