CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES · source records, page 14

273 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 273 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16273 / 273
EER2 · BTU/Wh10–12273 / 273
HSPF2 · BTU/Wh7.8–8.1273 / 273
Cooling capacity · BTU/h32,400–35,000273 / 273
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800273 / 273
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000273 / 273
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400273 / 273
COP at 5°F / −15°C2–2.44273 / 273
Equipment / loop typeHP - Split System273 / 273
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)273 / 273
Compressor stagingTwo-stage273 / 273
Connected capabilityNo273 / 273

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTM36C5CDS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21851868915.208.10177002.42EPA 4643191
CTM36C5CDS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21851868515.208.10181002.36EPA 4643195
CTM36C5CDS2+ furnace: Z8ES120C20LMPS1AHRI reference: 21851868115.208.10180002.36EPA 4643199
CTM36C5CDS2+ furnace: Z8ES120C20SMPS1AHRI reference: 21851867715.208.10180002.36EPA 4643203
CTM36C5CDS2+ furnace: Z8VT100C16SMPC1AHRI reference: 21851865315.208.10184002.40EPA 4643207
CTM36C5CDS2+ furnace: Z8VT080C16SMPC1AHRI reference: 21851864915.208.10184002.40EPA 4643211
CTU48C5XFS2+JME12C2SN2+TXVAHRI reference: 21863712015.208.10173002.00EPA 4664197
CTF48C5CFS2+JME12C2SN2AHRI reference: 21863711415.208.10173002.00EPA 4664203
CTU48C5XFS2+JME16C2SN2+TXVAHRI reference: 21863710715.208.10173002.00EPA 4664208
CTF48C5CFS2+JME16C2SN2AHRI reference: 21863710115.208.10173002.00EPA 4664212
CTM48C5CFS2+JME16C2SN2AHRI reference: 21863709515.208.10176002.42EPA 4664216
CTF36C5CDS2+JME12C2SN2AHRI reference: 21863708915.208.10176002.00EPA 4664221
CTM48C5CFS2+JME12C2SN2AHRI reference: 21863708315.208.10176002.42EPA 4664227

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →