CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

XH536E2S11

LX SERIES · source records, page 10

273 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity32,400–35,000BTU/h

Each efficiency range summarizes published EPA records for XH536E2S11. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 273 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16273 / 273
EER2 · BTU/Wh10–12273 / 273
HSPF2 · BTU/Wh7.8–8.1273 / 273
Cooling capacity · BTU/h32,400–35,000273 / 273
Heating capacity at 47°F / 8.3°C · BTU/h30,600–32,800273 / 273
Heating capacity at 17°F / −8.3°C · BTU/h20,400–22,000273 / 273
Heating capacity at 5°F / −15°C · BTU/h17,000–18,400273 / 273
COP at 5°F / −15°C2–2.44273 / 273
Equipment / loop typeHP - Split System273 / 273
Refrigerant / source-reported GWPR-454B (GWP:470 | Lower GWP)273 / 273
Compressor stagingTwo-stage273 / 273
Connected capabilityNo273 / 273

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
CTF48C5CFS2+ furnace: TL8E100C20UH11AHRI reference: 21851922915.207.80173002.00EPA 4642861 →
CTU48C5XFS2+TXV+ furnace: Z9ES080C16SMPS1AHRI reference: 21851921715.207.80172002.00EPA 4642865 →
CTF48C5CFS2+ furnace: Z9ES080C16SMPS1AHRI reference: 21851921315.207.80172002.00EPA 4642869 →
CTU48C5XFS2+TXV+ furnace: Z9ES080C20SMPS1AHRI reference: 21851920915.208.10178002.00EPA 4642873 →
CTF48C5CFS2+ furnace: Z9ES080C20SMPS1AHRI reference: 21851920515.208.10178002.00EPA 4642877 →
CTU48C5XFS2+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21851918515.208.10174002.00EPA 4642881 →
CTU48C5XFS2+TXV+ furnace: Z8ES120C16SMPS1AHRI reference: 21851918115.208.10174002.00EPA 4642885 →
CTF48C5CFS2+ furnace: Z8ES120C16LMPS1AHRI reference: 21851917715.208.10174002.00EPA 4642889 →
CTF48C5CFS2+ furnace: Z8ES120C16SMPS1AHRI reference: 21851917315.208.10174002.00EPA 4642893 →
CTU48C5XFS2+JMC17C2SN1+TXVAHRI reference: 21851916915.208.10173002.00EPA 4642897 →
CTF48C5CFS2+JMC17C2SN1AHRI reference: 21851916515.208.10173002.00EPA 4642901 →
CTU48C5XFS2+JMC16C2SN1+TXVAHRI reference: 21851914115.208.10172002.00EPA 4642905 →
CTF48C5CFS2+JMC16C2SN1AHRI reference: 21851913715.208.10172002.00EPA 4642909 →
CTU48C5XFS2+TXV+ furnace: Z8ET120C20LMPS1AHRI reference: 21851913315.208.10181002.38EPA 4642913 →
CTF48C5CFS2+ furnace: Z8ET120C20LMPS1AHRI reference: 21851912915.208.10181002.38EPA 4642917 →
CTU48C5XFS2+TXV+ furnace: Z8ET100C20LMPS1AHRI reference: 21851912515.208.10179002.40EPA 4642921 →
CTF48C5CFS2+ furnace: Z8ET100C20LMPS1AHRI reference: 21851912115.208.10179002.40EPA 4642925 →
CTU48C5XFS2+TXV+ furnace: Z8ET100C16LMPS1AHRI reference: 21851911715.208.10180002.38EPA 4642929 →
CTF48C5CFS2+ furnace: Z8ET100C16LMPS1AHRI reference: 21851911315.208.10180002.38EPA 4642933 →
CTU48C5XFS2+TXV+ furnace: Z9ET080C16SMPS1AHRI reference: 21851910915.208.10183002.32EPA 4642937 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →