CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

THF2B60T21

LX SERIES · source records, page 2

185 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity53,000–57,000BTU/h

Each efficiency range summarizes published EPA records for THF2B60T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 185 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16185 / 185
EER2 · BTU/Wh11–12185 / 185
HSPF2 · BTU/Wh7.8–8.1185 / 185
Cooling capacity · BTU/h53,000–57,000185 / 185
Heating capacity at 47°F / 8.3°C · BTU/h54,500–59,500185 / 185
Heating capacity at 17°F / −8.3°C · BTU/h37,400–39,000185 / 185
Heating capacity at 5°F / −15°C · BTU/h29,200–32,800185 / 185
COP at 5°F / −15°C2–2.46185 / 185
Equipment / loop typeHP - Split System185 / 185
Refrigerant / source-reported GWPR-410A (GWP:2088)185 / 185
Compressor stagingTwo-stage185 / 185
Connected capabilityNo185 / 185

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD60JXXN1+TXV+ furnace: Z8ES080C20SMPS1AHRI reference: 21241524015.208.10312002.36EPA 2478382
XAFD60JXXN1+TXV+ furnace: Z8ES080C16LMPS1AHRI reference: 21248177315.208.10314002.42EPA 2479535
XAHD60JXXN1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 21248174515.208.10310002.38EPA 2479618
XAHD60JBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 21248175215.208.10310002.38EPA 2479913
XAHD60JBCN1+ furnace: Z8ES120C20SMPS1AHRI reference: 21241516515.208.10312002.36EPA 2480297
XAFD60JBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241526515.208.10314002.42EPA 2480326
XAFC60HBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241479115.207.80310002.34EPA 2481556
XAHD60JXXN1+TXV+ furnace: Z8ES130D20SMPS1AHRI reference: 21241502015.208.10310002.38EPA 2481796
XAHD60JBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 21241502515.208.10310002.38EPA 2481801
XAHC60HBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241476615.207.80324002.34EPA 2481955
XAFD60HBCN1+ furnace: Z8ES080C16SMPS1AHRI reference: 21241477615.207.80310002.34EPA 2481960
XAFC60HBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21248000615.207.80310002.34EPA 2482184
XAFD60JXXN1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21248001915.208.10314002.40EPA 2482190
XAFD60JXXN1+TXV+ furnace: Z8ES130D20LMPS1AHRI reference: 21248496015.208.10314002.40EPA 2482332
XAFD60HBCN1+ furnace: Z8ES080C16LMPS1AHRI reference: 21248929915.207.80310002.34EPA 2482433
XAHD60JBCN1+ furnace: Z8ES120C16LMPS1AHRI reference: 21248932015.208.10310002.38EPA 2482440
XAHD60JXXN1+TXV+ furnace: Z8ES080C20LMPS1AHRI reference: 21248932715.208.10312002.36EPA 2482444
XAHD60JXXN1+TXV+ furnace: Z8ES120C16LMPS1AHRI reference: 21248931315.208.10310002.38EPA 2482447
XAHD60JBCN1+ furnace: Z8ES080C20LMPS1AHRI reference: 21248933415.208.10312002.36EPA 2482456
XAHD60JXXN1+TXV+ furnace: Z8ES120C20SMPS1AHRI reference: 21241516015.208.10312002.36EPA 2483187