CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

THF2B48T21

LX SERIES · source records, page 9

348 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–47,500BTU/h

Each efficiency range summarizes published EPA records for THF2B48T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 348 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16348 / 348
EER2 · BTU/Wh11–12348 / 348
HSPF2 · BTU/Wh7.8–8.1348 / 348
Cooling capacity · BTU/h44,500–47,500348 / 348
Heating capacity at 47°F / 8.3°C · BTU/h43,500–47,500348 / 348
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,200348 / 348
Heating capacity at 5°F / −15°C · BTU/h23,400–29,800348 / 348
COP at 5°F / −15°C2.22–2.84348 / 348
Equipment / loop typeHP - Split System348 / 348
Refrigerant / source-reported GWPR-410A (GWP:2088)348 / 348
Compressor stagingTwo-stage348 / 348
Connected capabilityNo348 / 348

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC60HBCN1+ furnace: TM8E120C20MP11AHRI reference: 21035788915.208.10238002.26EPA 3025982 →
XAFC60HBCN1+ furnace: TMLE120C20MP11AHRI reference: 21035789515.208.10238002.26EPA 3025999 →
XAFD60HBCN1+ furnace: TM8E080C16MP11AHRI reference: 21035794915.207.80234002.28EPA 3026009 →
XAFC60HBCN1+ furnace: TMLE080C16MP11AHRI reference: 21035798515.207.80234002.28EPA 3026018 →
XAFC60HBCN1+ furnace: TM8E080C16MP11AHRI reference: 21035797915.207.80234002.28EPA 3026021 →
XAFD60HBCN1+ furnace: TM8E130D20MP11AHRI reference: 21036086515.207.80240002.26EPA 3026023 →
XAFD60HBCN1+ furnace: TMLE080C16MP11AHRI reference: 21035796115.207.80234002.28EPA 3026024 →
XAFD60HBCN1+ furnace: TMLE130D20MP11AHRI reference: 21036087715.207.80240002.26EPA 3026032 →
XAHD60GBCN1+ furnace: TM8E130D20MP11AHRI reference: 21034443115.207.80244002.24EPA 3026114 →
XAHD60HBCN1+ furnace: TMLE130D20MP11AHRI reference: 21034580615.208.10254002.42EPA 3026187 →
XAFC60HBCN1+ furnace: TM8E100C16MP11AHRI reference: 21034582015.207.80234002.28EPA 3026194 →
XAFC60HBCN1+ furnace: TMLE100C16MP11AHRI reference: 21034582615.207.80234002.28EPA 3026196 →
XAFC60HBCN1+ furnace: TMLE080C20MP11AHRI reference: 21034584615.207.80238002.26EPA 3026206 →
XAFC60HBCN1+ furnace: TM8E080C20MP11AHRI reference: 21034584015.207.80238002.26EPA 3026207 →
XAHD60GBCN1+ furnace: TM8E100C20MP11AHRI reference: 21034756215.207.80240002.24EPA 3026219 →
XAHD60GBCN1+ furnace: TMLE100C20MP11AHRI reference: 21034756815.207.80240002.24EPA 3026220 →
XAHD60HBCN1+ furnace: TM8E130D20MP11AHRI reference: 21034580015.208.10254002.42EPA 3026224 →
XAHD60GBCN1+ furnace: TM8E120C20MP11AHRI reference: 21034824815.207.80240002.26EPA 3026233 →
XAHD60GBCN1+ furnace: TMLE120C20MP11AHRI reference: 21034825415.207.80240002.26EPA 3026238 →
XAHC60GBCN1+ furnace: TM8E100C20MP11AHRI reference: 21034826815.207.80240002.26EPA 3026242 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →