CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

THF2B48T21

LX SERIES · source records, page 15

348 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity44,500–47,500BTU/h

Each efficiency range summarizes published EPA records for THF2B48T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 348 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16348 / 348
EER2 · BTU/Wh11–12348 / 348
HSPF2 · BTU/Wh7.8–8.1348 / 348
Cooling capacity · BTU/h44,500–47,500348 / 348
Heating capacity at 47°F / 8.3°C · BTU/h43,500–47,500348 / 348
Heating capacity at 17°F / −8.3°C · BTU/h29,200–34,200348 / 348
Heating capacity at 5°F / −15°C · BTU/h23,400–29,800348 / 348
COP at 5°F / −15°C2.22–2.84348 / 348
Equipment / loop typeHP - Split System348 / 348
Refrigerant / source-reported GWPR-410A (GWP:2088)348 / 348
Compressor stagingTwo-stage348 / 348
Connected capabilityNo348 / 348

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAFC60HBCN1+JMVT16CC2N1AHRI reference: 21036020015.208.10236002.30EPA 3987615
XAHD60HBCN1+ furnace: TM9Y100C16MP11AHRI reference: 21036049515.208.10250002.46EPA 3987670
XAFC60HBCN1+ furnace: TM9Y080C16MP11AHRI reference: 21036050715.207.80238002.28EPA 3987680
XAFD60HBCN1+ furnace: TM9V120D20MP12AHRI reference: 21036052315.207.80236002.30EPA 3987694
XAFD60HBCN1+ furnace: TP9C120D20MP13AHRI reference: 21036053115.207.80236002.30EPA 3987702
XAFD60HBCN1+ furnace: TM9V100C20MP12AHRI reference: 21036055315.207.80238002.30EPA 3987718
XAFD60HBCN1+ furnace: TP9C100C20MP13AHRI reference: 21036056115.207.80238002.30EPA 3987721
XAHD60HBCN1+ furnace: TM9E100C16MP12AHRI reference: 21036059915.207.80250002.46EPA 3987734
XAFD60HBCN1+ furnace: TM9E080C20MP12AHRI reference: 21036061115.208.10238002.28EPA 3987744
XAHD60HBCN1+ furnace: TM9E080C16MP12AHRI reference: 21036062915.207.80250002.46EPA 3987791
XAHC60GBCN1+ furnace: TM8V100C16MP12AHRI reference: 21035955915.207.80238002.26EPA 3987828
XAHD60GBCN1+ furnace: TL9E100C20UH11AHRI reference: 21035966315.207.80240002.26EPA 3987933
XAHC60GBCN1+ furnace: TL8E080C16UH11AHRI reference: 21035969515.207.80238002.26EPA 3987940
XAFD60GBCN1+JMVT20DC2N1AHRI reference: 21035971115.208.10250002.42EPA 3987954
XAFC60GBCN1+JMVT17CC2N1AHRI reference: 21035973115.208.10250002.42EPA 3987971
XAFD60GBCN1+JMET18DS2N1AHRI reference: 21035974515.208.10254002.40EPA 3987978
XAHD60HBCN1+ furnace: TM9V100C20MP12AHRI reference: 21035981315.207.80250002.46EPA 3988020
XAHD60HBCN1+ furnace: TP9C100C20MP13AHRI reference: 21035981715.207.80250002.46EPA 3988021
XAHD60GXXN1+TXV+ furnace: TM9Y120D20MP11AHRI reference: 21034716315.207.80236002.24EPA 3988063
XAHD60GBCN1+ furnace: TM9Y120D20MP11AHRI reference: 21034716915.207.80236002.24EPA 3988068

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →