CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

THF2B42T21

LX SERIES · source records, page 19

430 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity39,500–42,000BTU/h

Each efficiency range summarizes published EPA records for THF2B42T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 430 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16430 / 430
EER2 · BTU/Wh11.7–12430 / 430
HSPF2 · BTU/Wh7.8–8.1430 / 430
Cooling capacity · BTU/h39,500–42,000430 / 430
Heating capacity at 47°F / 8.3°C · BTU/h37,400–41,000430 / 430
Heating capacity at 17°F / −8.3°C · BTU/h24,200–26,600430 / 430
Heating capacity at 5°F / −15°C · BTU/h18,400–22,600430 / 430
COP at 5°F / −15°C1.98–2.42430 / 430
Equipment / loop typeHP - Split System430 / 430
Refrigerant / source-reported GWPR-410A (GWP:2088)430 / 430
Compressor stagingTwo-stage430 / 430
Connected capabilityNo430 / 430

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD48FBCN1+ furnace: TM9E080C20MP12AHRI reference: 21035039715.208.10198002.12EPA 3987135 →
XAFD48FBCN1+ furnace: TM9E080C20MP12AHRI reference: 21035040915.208.10196002.04EPA 3987142 →
XAHD48FBCN1+ furnace: TM9Y080C16MP11AHRI reference: 21035171515.208.10186002.04EPA 3987840 →
XAHC48FBCN1+ furnace: TM9V080C16MP12AHRI reference: 21036272915.208.10193002.06EPA 3988490 →
XAHC48FBCN1+ furnace: TP9C080C16MP13AHRI reference: 21036273315.208.10193002.06EPA 3988492 →
XAFD48FBCN1+ furnace: TM9V080C16MP12AHRI reference: 21036274915.207.80193002.00EPA 3988500 →
XAFD48FBCN1+ furnace: TP9C080C16MP13AHRI reference: 21036275315.207.80193002.00EPA 3988505 →
XAHC48FBCN1+ furnace: TM9V060B12MP12AHRI reference: 21036276915.208.10189002.00EPA 3988513 →
XAHC48FBCN1+ furnace: TP9C060B12MP13AHRI reference: 21036277315.208.10189002.00EPA 3988516 →
XAFC48FXXN1+TXV+ furnace: TM9E080C20MP12AHRI reference: 21036280915.208.10196002.04EPA 3988647 →
XAFC48FBCN1+ furnace: TM9E080C20MP12AHRI reference: 21036281515.208.10196002.04EPA 3988650 →
XAFC48FXXN1+TXV+ furnace: TM8Y120C20MP11AHRI reference: 21036285715.208.10196002.04EPA 3988655 →
XAFC48FBCN1+ furnace: TM8Y120C20MP11AHRI reference: 21036286315.208.10196002.04EPA 3988659 →
XAHD48FBCN1+ furnace: TM8V100C16MP12AHRI reference: 21036291115.208.10204002.12EPA 3989223 →
XAHC48FBCN1+ furnace: TM8V080B12MP12AHRI reference: 21036294015.207.80189002.00EPA 3989229 →
XAFD48FBCN1+ furnace: TL8E080C16UH11AHRI reference: 21036303115.208.10193002.02EPA 3989297 →
XAHD60GBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 21247493815.208.10218002.36EPA 3990427 →
XAHD60GBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 21247494815.208.10218002.36EPA 3990431 →
XAHD60GBCN1+ furnace: Z8ES120C16SMPS1AHRI reference: 21247498715.208.10220002.36EPA 3990446 →
XAHC48FBCN1+ furnace: Z9ET100C20SMPS1AHRI reference: 21241541015.207.80224002.30EPA 3990478 →

Sources and documentation

The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.

No manufacturer manual has been matched to this model.

Collection method, revision history and known limitations →