CHAMPION HEATING AND COOLING / AIR-SOURCE HEAT PUMP

THF2B36T21

LX SERIES · source records, page 8

215 published source records · source checked Sep 21, 2026

SEER2 range15.2–16BTU/Wh
HSPF2 range7.8–8.1BTU/Wh
Cooling capacity33,400–36,000BTU/h

Each efficiency range summarizes published EPA records for THF2B36T21. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.

Model patterns and component strings are preserved exactly. How to read model patterns and combinations →

Heating performance & equipment details

Ranges include the 215 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.

Reported fieldValue / rangeRecords supplying it
SEER2 · BTU/Wh15.2–16215 / 215
EER2 · BTU/Wh11.7–12215 / 215
HSPF2 · BTU/Wh7.8–8.1215 / 215
Cooling capacity · BTU/h33,400–36,000215 / 215
Heating capacity at 47°F / 8.3°C · BTU/h32,600–34,800215 / 215
Heating capacity at 17°F / −8.3°C · BTU/h21,400–23,800215 / 215
Heating capacity at 5°F / −15°C · BTU/h16,500–20,000215 / 215
COP at 5°F / −15°C1.96–2.44215 / 215
Equipment / loop typeHP - Split System215 / 215
Refrigerant / source-reported GWPR-410A (GWP:2088)215 / 215
Compressor stagingTwo-stage215 / 215
Connected capabilityNo215 / 215

47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.

Matched systems

Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.

Indoor unit / required furnaceSEER2BTU/WhHSPF2BTU/WhHeating capacity at 5°F / −15°CBTU/hCOP at 5°F / −15°CRecord & comparison
XAHD48FBCN1+ furnace: TM9V120D20MP12AHRI reference: 21035613815.207.80174002.10EPA 3987317
XAHD48FBCN1+ furnace: TP9C120D20MP13AHRI reference: 21035614215.207.80174002.10EPA 3987323
XAHD48FBCN1+ furnace: TM9E100C16MP12AHRI reference: 21035615415.207.80175002.08EPA 3987327
XAHC48FBCN1+ furnace: TM9E080B12MP12AHRI reference: 21035616615.207.80177002.04EPA 3987330
XAHC48FBCN1+ furnace: TM9V100C16MP12AHRI reference: 21035428615.207.80177002.08EPA 3987378
XAHC48FBCN1+ furnace: TP9C100C16MP13AHRI reference: 21035429015.207.80177002.08EPA 3987380
XAHC48FBCN1+ furnace: TL9E060B12UH11AHRI reference: 21035441915.207.80174002.06EPA 3987386
XAFD48FBCN1+JMVT20DC2N1AHRI reference: 21035442715.208.10176002.08EPA 3987388
XAFC48FBCN1+JMET12CS2N1AHRI reference: 21035444915.208.10176002.04EPA 3987393
XAHD48FBCN1+ furnace: TM8V100C16MP12AHRI reference: 21036219315.207.80174002.06EPA 3987413
XAHD48FBCN1+ furnace: TM8V080C16MP12AHRI reference: 21036219715.207.80174002.06EPA 3987417
JHETC42FBCS2N1AHRI reference: 21035446115.208.10176002.06EPA 3987418
XAHD48FBCN1+ furnace: TM9E080C16MP12AHRI reference: 21036210115.207.80175002.08EPA 3987699
JHVTC42FBCC2N1AHRI reference: 21035142015.208.10173002.08EPA 3987747
XAHC36DBCN1+JMET16CS2N1AHRI reference: 21035317815.207.80172002.12EPA 3987899
XAHB36DBCN1+JMVT12BC2N1AHRI reference: 21035316815.207.80172002.08EPA 3987923
XAFC36DBCN1+JMET12CS2N1AHRI reference: 21035319015.207.80168002.00EPA 3987928
XAHD48FBCN1+ furnace: TM9Y100C16MP11AHRI reference: 21035321415.207.80178002.04EPA 3987972
XAFC48FXXN1+TXV+ furnace: TL8E100C20UH11AHRI reference: 21035137815.207.80176002.04EPA 3988228
XAFC48FBCN1+ furnace: TL8E100C20UH11AHRI reference: 21035138215.207.80176002.04EPA 3988232