HMH72B341
HMH7 · source records, page 23
785 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HMH72B341. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 785 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 785 / 785 |
| EER2 · BTU/Wh | 9–10.5 | 785 / 785 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 785 / 785 |
| Cooling capacity · BTU/h | 31,400–35,200 | 785 / 785 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 785 / 785 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 785 / 785 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 785 / 785 |
| COP at 5°F / −15°C | 1.8–2.18 | 785 / 785 |
| Equipment / loop type | HP - Split System | 785 / 785 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 785 / 785 |
| Compressor staging | Continuously variable | 785 / 785 |
| Connected capability | No | 785 / 785 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFB36DXXN1+TXV+ furnace: TM9V040A10MP12Cold climate designationAHRI reference: 211388504 | 17.00 | 8.10 | 23400 | 2.00 | EPA 2484205 → |
XAFC48FBCN1+ furnace: TM8E080C16MP11Cold climate designationAHRI reference: 211385858 | 17.00 | 8.50 | 23400 | 2.06 | EPA 2484461 → |
XAFC48FBCN1+ furnace: TMLE080C16MP11Cold climate designationAHRI reference: 211385890 | 17.00 | 8.50 | 23400 | 2.06 | EPA 2484471 → |
XAFC36DBCN1+ furnace: TM9V080B12MP12Cold climate designationAHRI reference: 211387826 | 17.00 | 8.10 | 24400 | 2.06 | EPA 2484498 → |
XAFD48FXXN1+TXV+ furnace: TP9C120D20MP13Cold climate designationAHRI reference: 211394347 | 17.00 | 8.50 | 23800 | 2.10 | EPA 2484527 → |
XAFD48FBCN1+ furnace: TM9V120D20MP12Cold climate designationAHRI reference: 211394364 | 17.00 | 8.50 | 23800 | 2.10 | EPA 2484534 → |
XAFD48FBCN1+ furnace: TP9C120D20MP13Cold climate designationAHRI reference: 211394379 | 17.00 | 8.50 | 23800 | 2.10 | EPA 2484538 → |
XAFD48FBCN1+ furnace: TM8E120C16MP11Cold climate designationAHRI reference: 211398243 | 17.00 | 8.50 | 23600 | 2.08 | EPA 2485015 → |
XAFC48FXXN1+TXV+ furnace: TM8E120C16MP11Cold climate designationAHRI reference: 211398273 | 17.00 | 8.50 | 23600 | 2.08 | EPA 2485019 → |
XAHC36DXXN1+TXV+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 211389932 | 17.00 | 8.10 | 24600 | 2.08 | EPA 2485142 → |
XAHC36DXXN1+TXV+ furnace: TMLV100C16MP12Cold climate designationAHRI reference: 211389946 | 17.00 | 8.10 | 24600 | 2.08 | EPA 2485148 → |
XAFC48FXXN1+TXV+ furnace: TM8E080B12MP11Cold climate designationAHRI reference: 211385973 | 17.00 | 8.50 | 23800 | 2.04 | EPA 2485401 → |
XAFC48FXXN1+TXV+ furnace: TMLE080B12MP11Cold climate designationAHRI reference: 211385985 | 17.00 | 8.50 | 23800 | 2.04 | EPA 2485402 → |
XAFC48FBCN1+ furnace: TM8E080B12MP11Cold climate designationAHRI reference: 211385999 | 17.00 | 8.50 | 23800 | 2.04 | EPA 2485408 → |
XAHC36DBCN1+ furnace: TM8V100C16MP12Cold climate designationAHRI reference: 211390000 | 17.00 | 8.10 | 24600 | 2.08 | EPA 2485432 → |
XAHC36DBCN1+ furnace: TM8V080C16MP12Cold climate designationAHRI reference: 211390013 | 17.00 | 8.10 | 24600 | 2.08 | EPA 2485439 → |
XAFC48FBCN1+ furnace: TMLE080B12MP11Cold climate designationAHRI reference: 211386029 | 17.00 | 8.50 | 23800 | 2.04 | EPA 2485708 → |
XAHB36DBCN1+ furnace: TM8E060A12MP11Cold climate designationAHRI reference: 211392554 | 17.00 | 8.10 | 23400 | 2.00 | EPA 2485738 → |
XAHB36DBCN1+ furnace: TMLE060A12MP11Cold climate designationAHRI reference: 211392565 | 17.00 | 8.10 | 23400 | 2.00 | EPA 2485744 → |
XAHC36DXXN1+TXV+ furnace: TL8E100C20UH11Cold climate designationAHRI reference: 211393313 | 17.00 | 8.10 | 24400 | 2.10 | EPA 2485773 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →