Heating performance & equipment details
Ranges include the 785 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.5–18.5 | 785 / 785 |
| EER2 · BTU/Wh | 9–10.5 | 785 / 785 |
| HSPF2 · BTU/Wh | 8.1–8.5 | 785 / 785 |
| Cooling capacity · BTU/h | 31,400–35,200 | 785 / 785 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 31,400–34,800 | 785 / 785 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 24,600–27,000 | 785 / 785 |
| Heating capacity at 5°F / −15°C · BTU/h | 22,200–25,000 | 785 / 785 |
| COP at 5°F / −15°C | 1.8–2.18 | 785 / 785 |
| Equipment / loop type | HP - Split System | 785 / 785 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 785 / 785 |
| Compressor staging | Continuously variable | 785 / 785 |
| Connected capability | No | 785 / 785 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAFB36DBCN1+ furnace: TM9E060A10MP12Cold climate designationAHRI reference: 211389199 | 17.50 | 8.10 | 23800 | 2.02 | EPA 2479658 → |
XAFB36DXXN1+TXV+ furnace: TM8V060A12MP12Cold climate designationAHRI reference: 211391002 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2479705 → |
XAHC36DBCN1+ furnace: TM8E100B12MP11Cold climate designationAHRI reference: 211391614 | 17.50 | 8.10 | 23400 | 2.02 | EPA 2479720 → |
XAFC36DBCN1+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 211388850 | 17.50 | 8.10 | 24400 | 2.06 | EPA 2479858 → |
XAHC36DBCN1+ furnace: TM8E080B12MP11Cold climate designationAHRI reference: 211392171 | 17.50 | 8.10 | 23400 | 2.02 | EPA 2480089 → |
XAHC36DBCN1+ furnace: TMLE080B12MP11Cold climate designationAHRI reference: 211392187 | 17.50 | 8.10 | 23400 | 2.02 | EPA 2480090 → |
XAFC36DXXN1+TXV+ furnace: TP9C060B12MP13Cold climate designationAHRI reference: 211388227 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2480264 → |
XAFC36DXXN1+TXV+ furnace: TM9E080B12MP12Cold climate designationAHRI reference: 211388835 | 17.50 | 8.10 | 24400 | 2.06 | EPA 2480285 → |
XAFC36DXXN1+TXV+ furnace: TM9V100C16MP12Cold climate designationAHRI reference: 211387504 | 17.50 | 8.50 | 24000 | 2.10 | EPA 2480294 → |
XAFC36DXXN1+TXV+ furnace: TP9C080C16MP13Cold climate designationAHRI reference: 211387636 | 17.50 | 8.10 | 23800 | 2.08 | EPA 2480295 → |
XAFB36DBCN1+ furnace: TMLV060A12MP12Cold climate designationAHRI reference: 211391077 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2480417 → |
XAFB36DBCN1+ furnace: TPLC060A12MP13Cold climate designationAHRI reference: 211391107 | 17.50 | 8.10 | 24200 | 2.06 | EPA 2480426 → |
XAHC36DBCN1+ furnace: TMLE100B12MP11Cold climate designationAHRI reference: 211391627 | 17.50 | 8.10 | 23400 | 2.02 | EPA 2480456 → |
XAHC36DXXN1+TXV+ furnace: TM9E080C16MP12Cold climate designationAHRI reference: 211388664 | 17.50 | 8.10 | 24400 | 2.06 | EPA 2480619 → |
XAFC36DBCN1+ furnace: TL8E100C20UH11Cold climate designationAHRI reference: 211393375 | 17.50 | 8.50 | 24000 | 2.12 | EPA 2480848 → |
XAFC36DXXN1+TXV+ furnace: TL8E100C20UH11Cold climate designationAHRI reference: 211393360 | 17.50 | 8.50 | 24000 | 2.12 | EPA 2480886 → |
XAFC48FBCN1+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211394098 | 17.50 | 8.50 | 24200 | 2.06 | EPA 2480930 → |
XAFD48FXXN1+TXV+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211394055 | 17.50 | 8.50 | 23600 | 2.06 | EPA 2481061 → |
XAFC48FXXN1+TXV+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211394085 | 17.50 | 8.50 | 24200 | 2.06 | EPA 2481064 → |
XAFD48FBCN1+ furnace: TM9Y080C16MP11Cold climate designationAHRI reference: 211394070 | 17.50 | 8.50 | 23600 | 2.06 | EPA 2481137 → |