HL19B6021
MOMENTUM
18 published source records · source checked Sep 21, 2026
Each efficiency range summarizes published EPA records for HL19B6021. The highest SEER2 and HSPF2 may belong to different combinations. Open a source record below to see its ratings and the scope of its component information.
Model patterns and component strings are preserved exactly. How to read model patterns and combinations →
Heating performance & equipment details
Ranges include the 18 published source records for this model. Values in different rows may describe different configurations. Open an individual record to compare values from the same test configuration.
| Reported field | Value / range | Records supplying it |
|---|---|---|
| SEER2 · BTU/Wh | 15.2–16 | 18 / 18 |
| EER2 · BTU/Wh | 11.7 | 18 / 18 |
| HSPF2 · BTU/Wh | 7.8 | 18 / 18 |
| Cooling capacity · BTU/h | 54,000–55,000 | 18 / 18 |
| Heating capacity at 47°F / 8.3°C · BTU/h | 59,000–60,000 | 18 / 18 |
| Heating capacity at 17°F / −8.3°C · BTU/h | 40,000–40,500 | 18 / 18 |
| Heating capacity at 5°F / −15°C · BTU/h | 32,400–33,400 | 18 / 18 |
| COP at 5°F / −15°C | 2.08–2.28 | 18 / 18 |
| Equipment / loop type | HP - Split System | 18 / 18 |
| Refrigerant / source-reported GWP | R-410A (GWP:2088) | 18 / 18 |
| Compressor staging | Two-stage | 18 / 18 |
| Connected capability | No | 18 / 18 |
47°F = 8.3°C; 17°F = −8.3°C; 5°F = −15°C. COP is dimensionless. These are reported rating points, not a prediction of a particular home’s heat demand or operating limit.
Matched systems
Each row is one source record. The component column distinguishes listed combinations from outdoor-model ratings without an indoor configuration.
| Indoor unit / required furnace | SEER2BTU/Wh | HSPF2BTU/Wh | Heating capacity at 5°F / −15°CBTU/h | COP at 5°F / −15°C | Record & comparison |
|---|---|---|---|---|---|
XAHD60JBCN1+JMVT20DC2N1AHRI reference: 209375413 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624720 → |
XAFD60JBCN1+JMET18DS2N1AHRI reference: 210296171 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624725 → |
JHETD60JBCS2N1AHRI reference: 210296591 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624729 → |
XAFD60JBCN1+JMVT20DC2N1AHRI reference: 210297333 | 16.00 | 7.80 | 32400 | 2.10 | EPA 3624733 → |
XAFD60JBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 212487501 | 15.20 | 7.80 | 33400 | 2.28 | EPA 2476602 → |
XAFD60JBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 212487482 | 15.20 | 7.80 | 33400 | 2.28 | EPA 2477410 → |
XAHD60JBCN1+ furnace: Z8ES120C20SMPS1AHRI reference: 212489257 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2478506 → |
XAHD60JBCN1+ furnace: Z8ES120C20LMPS1AHRI reference: 212489262 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2478869 → |
XAHD60JBCN1+ furnace: Z8ES130D20SMPS1AHRI reference: 212480953 | 15.20 | 7.80 | 32600 | 2.22 | EPA 2480641 → |
XAHD60JBCN1+ furnace: Z8ES080C20LMPS1AHRI reference: 212480978 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2480956 → |
XAHD60JBCN1+ furnace: Z8ES080C20SMPS1AHRI reference: 212480973 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2480962 → |
XAHD60JBCN1+ furnace: Z8ES130D20LMPS1AHRI reference: 212480958 | 15.20 | 7.80 | 32600 | 2.22 | EPA 2484437 → |
XAHD60JBCN1+ furnace: Z8ES100C20SMPS1AHRI reference: 212476469 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2485927 → |
XAHD60JBCN1+ furnace: Z8ES100C20LMPS1AHRI reference: 212476474 | 15.20 | 7.80 | 32600 | 2.14 | EPA 2485932 → |
XAHD60JBCN1+ furnace: TM9E080C20MP12AHRI reference: 209375353 | 15.20 | 7.80 | 32400 | 2.08 | EPA 3624713 → |
XAHD60JBCN1+JMET18DS2N1AHRI reference: 209375417 | 15.20 | 7.80 | 32400 | 2.16 | EPA 3624721 → |
XAHD60JBCN1+ furnace: Z8ET100C20LMPS1AHRI reference: 212594450 | 15.20 | 7.80 | 32600 | 2.14 | EPA 3991307 → |
XAHD60JBCN1+ furnace: Z8ET120C20LMPS1AHRI reference: 212594630 | 15.20 | 7.80 | 32600 | 2.14 | EPA 3991441 → |
Sources and documentation
The table uses public EPA ENERGY STAR data. AHRI references are reported by EPA and have not been independently checked with AHRI. Source records do not establish availability, installation suitability or rebate eligibility.
No manufacturer manual has been matched to this model.
Collection method, revision history and known limitations →